Operating Instructions
WSU/WEU 26/2
Receiver unit
Outputs
Response time
Current
Voltage
Power (DC/AC)
Mech. life expectancy
(lifetime)
Electr. life expectancy
(lifetime)
DC at 2 A current
AC at 2 A current
Switch-on time
Normally-open contacts
Normally-closed contacts
Power consumption
Version 24 V DC
Version 115 V AC
Version 230 V AC
Operating data
Connection
Safety category
Tested to
Ambient operating temperature
Storage temperature
Air humidty (non-condensing)
Dimensions
Vibration resistance
Shock resistance
Weight
Sender unit
Receiver unit
8 008 631/P134/20-12-04 © SICK AG • Safety Systems • Germany • All rights reserved
Technical Data
min.
typ.
Relay max. operating frequency 0,2 Hz
(1 operation in 5 s)
0.02 A
24 V DC
10 ms
9 ms
6 W
10 VA
10 VA
Connecting cables (PG 13,5)
Connectors
Type 4
EN 61 496 part 1and pr EN 50 100 part 2
–25 °C
–25 °C
15 %
see Dimensional Drawings, Appendix
5 g, 10 ... 55 Hz to IEC 68-2-6
10 g, 16 ms to IEC 68-2-29
0.9 kg
1.0 kg
GB
Chapter 9
max.
22 ms
2 A
250 V AC
144 W /
1380 VA
7
10
3
80 x 10
3
50 x 10
+55 °C
+70 °C
95 %
1.3 kg
1.4 kg
167