23
GFCI personal protection switch (*)
Fig. 14
(figure 14).
The GFCI personal protection switch is spe-
cifically for your protection; therefore, do not
misuse it as on On/Off switch.
If the GFCI personal protection switch is dam-
aged, e.g. due to contact with water, do not
use it any more.
The GFCI personal protection switch is indis-
pensable; it is used for protection of the
power tool operator against electric shock.
Under fault-free operation, the control lamp
of the GFCI personal protection switch lights
up red.
Check the operability of the GFCI personal
protection switch before beginning to work:
1. Connect the plug of the GFCI personal pro-
tection switch with the mains socket outlet.
2. Press the RESET–button. The indication
light on the GFCI personal protection switch
lights up red.
3. Disconnect the plug from the socket outlet.
The red indication light goes out.
4. Repeat steps 1. and 2.
5. Press the TEST–button; the red indication
light goes out. If the red indication light does
not go out, do not run the machine. In this
case, contact the customer service.
6. Press the RESET–button; when the indica-
tion light lights up red, the machine can now
be switched on.
Do not use the GFCI personal protection switch
for switching the power tool on and off.