Accessories Kit - Lowara GEM Instrucciones Para La Instalación Y El Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

7.4
Priming kit
7.4.1
Priming tank
The priming tank is used for suction lift installations and serves to keep the
body of the pump and the inlet pipe full of water, even if the base valve is leaking. Each pump must have its own independent
priming tank, placed at a higher level than the pump. The tank must be connected to a water source for adding water and
keeping it full. The diameter of the connecting pipe to the pump depends on the use class. The recirculation return pipe can be
connected to the tank which must also have an overflow outlet. A level switch automatically activates the service pump if the
level of the tank drops and is not topped up. The hydraulic connections must be made by the fitter.
7.4.2

Accessories kit

The available accessories kit includes:
- Filling and discharge valves, reductions, non-return valve. Device for monitoring ON/OFF status excluding, available on
request. Assembly and electrical connections by customer. Valve lock kit available on request.
- Float switch tap complete with ring nut for fixing to the tank through-hole.
- Level indicator to be connected to the electric panel.
75, 100, 150 and 200 cm high tank supports are available on request.
M
E
L
NAME
1
Priming tank *
2
Float valve *
3
1" filling ball valve *
4
Level switch *
5
2" non-return valve *
6
2" pump inlet valve, always open *
7
2" discharge ball valve *
A
Tank supply
B
Overflow
* items included in supply
Rp1"1/2
C
G
F
D
Rp1"1/2
B
1
Rp1"
Rp2"
6
5
N
NAME
C
To drain
D
Connection to service pump delivery line
E
To system
F
Single-threshold pressure switch
G
To tank
H
Pump
L
Motor
M
Service pump control panel
N
Jockey pump primer, if required
En-acc-adesc_c_tc
65
2
Rp1"
Rp2"
7
C
3
A
4

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Gemj

Tabla de contenido