80446222
11. CONTROL AND mAINTENANCE
9. Insert new cover O-ring (18) according to the diagram.
10. Clean the sealing surfaces of the cover.
11. Put on the cover (17) with the new O-ring and carefully
12. Clean the sealing surfaces () at the condensate
ingersollrandproducts.com
tighten the four cover screws (16) crosswise (8 Nm).
receiver tank (19).
EN
17