8. FuNCTION

Via the inlet line (1) the condensate flows into the ENL 10
and accumulates in the housing (2).
A capacitive functioning sensor () continuously registers
the filling level and relays a signal to the electronic control as
soon as the container is filled.
The pilot valve (4) is activated and the membrane () opens
the outlet line to discharge the condensate (6).
When the ENL 10 is empty, the outlet line is reclosed tightly
in time before unnecessary compressedair losses occur.
At the ENL 10, two LEDs indicate the individual operating
states.
When applying supply voltage, the ENL 10 carries out a self-
test.
Both LEDs are lit for approximately 1 second, subsequently,
the device changes over to the "ready-to-operate" state.
Ready to operate, voltage is applied.
In the event that the condensate discharge is disturbed, an
alarm mode will start which is indicated by the flashing of
the red alarm LED.
malfunction/alarm
Test of the valve function (manual drainage): press and hold
the button for approximately 2 s.
Test of the alarm function (see below): press and hold the
button for at least 1 min.
Do not use for permanent drainage.