SW24.W
Number of control panel pow-
er-ups counter
Reading of the number of control
panel power-ups
PONC
In the example shown above, the control
panel was powered up 2547 times (it could
indicate a poor quality mains electricity, with
frequent power cuts)
Reset number of control panel
power-ups counter
PONE
Waiting press OK for 5 s to reset
the counter to 0
Number of self-reset counter
Reading of the number of control
panel self-resets
A self-reset is a reset of the microswitch by
the control panel for safety reasons.
Typically the control panel goes to self-reset
RSTC
when the minimum microswitch voltage
threshold has been reached. An excessive
number of self-resets could indicate a poor
quality power supply, subject to strong volt-
age fluctuation.
Reset number of self-reset
counter
RSTE
Waiting press OK for 5 s to reset
the counter to 0
Installer telephone settings and
display
Press OK briefly to view the saved
number (use buttons ▲▼ to scroll)
First 4 digits of the installer number
Next 4 digits of the installer
TL
number
Last 2 digits of the installer number
In the example shown above the installer
telephone number is: 333 4254832
Press OK for 5 s to enter the number edit
mode. Use buttons ▲▼ to change the value,
use OK to confirm the digit
Control panel info display
INF
Control panel name
Control panel firmware version
Connection module
Sub
Description
menu
Connection module on CNX1
connector
CNX1
No module connected
Wi-Fi module EMC.W connected
24
Restore default values and loading from
memory card
Sub
Description
2547
menu
Loading the default values
Waiting press OK for 5 s to load
the default values.
Note:
DEF
Loading the default values then requires the
travel to be calibrated again, LRNT flashes
oooo
on the display until (rapid or advanced)
calibration is done.
Loading the programming from
1123
memory card
Waiting press OK for 5 s to load
the values from memory card."
MEM
Loading from memory card com-
pleted OK.
Loading from memory card error
(e.g. no card).
Control panel protection level settings
(default = OFF)
OFF
No protection
Protection of menus MOT, LRNT, TRV, OUT,
1
IN, LGC, STAT, EXP, LOAD
oooo
2
Protection of menu RAD
Protection from IP connection (it is not pos-
3
sible to connect to the control panel from a
smartphone)
Protection of menus MOT, LRNT, TRV, OUT,
4
IN, LGC, STAT, EXP, LOAD and IP connec-
3334
tion
2548
5
Protection of menu RAD and IP connection
6
Complete control panel protection
32
Protection of all board menus, IP connection
7
available
Note:
The password must be entered in the control panel each
time you wish to access a protected menu. If the pass-
word entered is incorrect access to the menu is denied.
SL24.W
1.13
Values
(default)
(1)
OFF
1
EN
Msg
display
oooo
oooo
DONE
EMEM