1) Place cord into clamp and secure to discharge pipe as shown in clamp detail (see Figure F).
NOTE: Do not install the cord under the hose clamp.
2) Tighten the hose clamp with a screwdriver. NOTE: Do not over tighten; over tightening may cause damage to the plastic clamp.
3) Make sure the float cable is not allowed to touch the excess hose clamp band during operation.
4) The float switch must be suspended seven inches below desired activation level (see Figure G).
CLAMP DETAIL
TETHER LENGTH
FOR ALARM FLOAT
Figure F
LIFT PUMP
Suspend control switch above pump turn on level. If a pump failure causes high-level condition, the APak
HOLDING TANK
Suspend control switch into tank 7" (17.8 cm) below desired alarm level. APak
Connect the two conductors from the control or mechanical switch to the terminations on the bottom of the alarm unit (see Figure B). The control switch operates on
low voltage to reduce shock hazards.
OPERATION AND TEST
Check and test your installation by lifting the float manually (see Figure E or G). The alarm unit will indicate an alarm condition by beeping and lighting a red LED above
"Input 1". The alarm may be silenced for 24 hours by briefly pressing Silence button. Once silenced, the LED changes to a flashing state, and the audible horn will not
sound. Once the high-water condition is remedied, the alarm should be reset by holding the Silence button for 3 seconds. Zoeller Company cannot be responsible for
damages caused by faulty or negligent installation of this device. We respectfully suggest you engage the services of a qualified licensed electrician or service person.
Hold the Silence button for more than 3 seconds to Test once per week to verify proper operation.
MECHANICAL FLOAT SWITCH
7" (17.8 cm)
SK1301F
CONTROL/MECHANICAL SWITCH WIRING
For internet connectivity, see the Z Control
© Copyright 2021 Zoeller
(10-4012)
7"
Figure G
Alarm System will activate (see Figure A).
®
Alarm System will activate if float ascends to alarm level (see Figure G).
®
Enabled APak
10-4013, 10-4014.
®
®
Co. All rights reserved.
®
CLAMP
DETAIL
ALARM
LEVEL
SK1301G