Page 10
Retrofit Installation
11
Install Knockout Plate, Connect Wires and Install Wiring Panel
• Use proper UL-approved connectors to secure wiring to the Knockout Plate provided in Parts Bag.
• Connect wires as shown in wiring diagram.
Attach cable clamp to Knockout
1
Plate. Knockout Plate mounts to
inside of Housing and may be
2
Screw from
Parts Bag
oriented as
desired.
Screw set
aside in
Step 6
Connect
3
wires
120 VAC
LINE IN
5
MASTER
WALL
SWITCH
BLK
WHT
GRD
BLACK
ORANGE
WHITE
BROWN
MASTER
WALL
SWITCH*
SWITCH BOX
* purchase separately
4
14/2
BLK
WHT
GRD
GROUND
(green or bare)
KNOCKOUT
120 VAC
LINE IN
ZB110H Installation Guide
6
BLK
RED
FAN
BLK
BRN
SENSOR/
CONTROL
ORG
WHT
RECEPTACLES
PLATE