Both TOF/Start versions feature a blanking function. The
TOF/Start triggers the output when objects are dynamic
(moving) within the detection field. Static objects within the
detection field will be ignored and blanked out (after 30
seconds). This covers with objects that are already present
at power up (i.e. bollards).
Start-up:
LED dimmed
Figure 13:
Active blanking - start-up sequence with i.e. bollards.
Figure 14:
After start-up the bollards are blanked out
from the detection field.
Active blanking:
Figure 15:
The detection field is free.
8
LED dimmed
LED bright
LED dimmed
LED dimmed
Figure 16:
A static object is placed in the detection field
LED dimmed
(i.e a trash bag). The object will be detected.
Figure 17:
After 30 s the static object will be blanked out and
the TOF/Start continues its operation with the new
geometry of the detection field.
13. Trouble shooting
Status
LED off
Object in the safeguarded
area and LED dimmed
red
No object in the
safeguarded area and
LED bright red
LED bright
If the problem persists, please contact your local CEDES
representative (www.cedes.com).
English
LED bright
LED dimmed
Action
Check supply power
Check electrical
connections
Check distance setting
Check electrical
connections
Check distance setting
LED dimmed