1. FEATURES
Brio 2000 is designed to automatize the starting and stopping operations of
an electric pump with regard to a drop in pressure (opening of the taps) and to
the stopping of the flow through the system (closing of the taps), respectively.
Brio 2000 stops the pump when senses the lack of water flow, preventing it
from any damaging dry operation.
Furthermore, thanks to a timer, it starts the pump automatically to verify an
eventual new water availability in the suction line – Brio2000-T and 2000-MT
versions only.
It is advisable using Brio 2000 with water systems whose water is without
sediments. In case it is not possible, it is necessary to install a filter before the
inlet of the device.
The pressure gauge checks the starting pressure value and the pressure in
the system.
Furthermore it verifies any possible presence of water leakages in the very
system.
PLEASE READ THIS INSTRUCTION LEAFLET CAREFULLY THROUGH
BEFORE INSTALLING AND OPERATING THE DEVICE.
ALL WIRING UP MUST BE CARRIED OUT BY SPECIALLY TRAINED
PERSONNEL.

2. SAFETY REGULATIONS

To avoid shocks and fire risks, read and follow closely the
!
following instructions:
Always unplug the device from the mains before carrying out any
work on it.
Be sure that the electric line connecting the device to the mains
and the extension leads have a cross-section suitable for pump
power and be sure that the electrical connections are far away from
any water source.
When Brio 2000 is used for swimming pools, ponds and fountains it
is necessary to use an automatic RCD with IDn=30mA protection.
WARNING: when the pump stops the pipes are under pressure
consequently we recommend opening a tap to discharge the system
before carrying out any work.