People Counter RAZL-2CO (Translation)
7 Fixing
It is recommended that the pillars be fixed to the ground to ensure a permanent and consistent detection of persons.
The two pillars must be aligned parallel and flat before the final fixing.
The adjustment mode, which is automatically activated after switching on (see previous sections "Adjustment Mode / Pillar Alignment " and "Adjustment
Mode / Check Alignment"), is helpful here.
Alternatively, the adjustment mode can be activated manually via the configuration interface (see section "Activating adjustment mode manually" below).
To ensure the most accurate detection of people, the sensor system is limited to a range of 2 m.
Before fixing, it should be determined on which side a power connection is available.
The sensor pillar must be located on the side with a power connection.
The distance between the pillars should not
exceed 2 m.
The two pillars must be aligned in a parallel
plane.
7.1 Attach stickers
After mounting, the 4 supplied stickers
stickers should be attached to the pillars.
2 stickers in
direction of exit
direction of entrance
Fiessler Elektronik GmbH & Co. KG
Buchenteich 14, D-73773 Aichwald
2 long holes for fixing with swivel range
3 threaded holes for M10 worm screws to compensate uneven floors
Mounting screws and worm screws are not included
2 stickers in
Phone: +49 (0)711 - 91 96 97 - 0
Fax: +49 (0) 711 - 91 96 97 - 50
-32-
Internet: http://fiessler.de
E-Mail: info@fiessler.de