NOTE: The triple burner has only two injectors, one injector mounted in the center and another mounted below
the cover plate� To access the second injector, remove the two screws and the cover plate�
24" Burner and Orifice Characteristic Table
Refer to the following chart for correct gas orifice spud placement�
IMPORTANT: Save the orifices removed from the appliance for future use�
Burner
Auxiliary
Semi-Rapid
Triple
Rapid
24" SERIES OF PRODUCTS
Gas Type: Natural Gas 4" Test Point Pressure
Burner
Large
Small
Tiny
Top Burner
Bottom Burner
Gas Type: LPG 10" Test Point Pressure
Burner
Large
Small
Tiny
Top Burner
Bottom Burner
Orifice
Position
Diam� (mm)
0�9
Front R
0�58
1�17
Rear L
0�75
0�93 + 1�82
Front L
1�14 + 0�56
1�6
Raer R
1�03
Gas
Type
NG
LP (Propane)
NG
LP (Propane)
NG
LP (Propane)
NG
LP (Propane)
Injector Size (mm)
0�99 mm x 5
1�29 mm
1�10 mm
1�40 mm
1�70 mm
Injector Size (mm)
0�56 mm x 5
0�80 mm
0�70 mm
0�85 mm
1�10 mm
18
Pressure
Rate
[i�w�c]
[BTU/h]
4"
5000
10"
5000
4"
6859
10"
6859
4"
17357
10"
15000
4"
6859
10"
6859
Burner Rating (BTU)
17400
6900
5000
7900
10700
Burner Rating (BTU)
15000
6500
5000
7900
10800