USING 6V NORM [PRESS & HOLD]
6V NORM charge mode is designed for 6-volt lead-acid
batteries only, like Wet Cell, Gel Cell, Enhanced Flooded,
Maintenance-Free and Calcium batteries. Consult the
battery manufacturer before using this mode.
USING 12V LITHIUM [PRESS & HOLD]
12V Lithium charge mode is designed for 12-volt lithium-
ion batteries only, including lithium iron phosphate.
CAUTION USE THIS MODE WITH CARE. THIS MODE IS
FOR 12-VOLT LITHIUM BATTERIES ONLY. LITHIUM-ION
BATTERIES ARE MADE AND CONSTRUCTED IN DIFFER-
ENT WAYS AND SOME MAY OR MAY NOT CONTAIN A
BATTERY MANAGEMENT SYSTEM (BMS). CONSULT
THE LITHIUM BATTERY MANUFACTURER BEFORE
CHARGING AND ASK FOR RECOMMENDED CHARGING
RATES AND VOLTAGES. SOME LITHIUM-ION BATTERIES
MAY BE UNSTABLE AND UNSUITABLE FOR CHARGING.
MAKE SURE YOU PURCHASE YOUR LITHIUM-ION BAT-
TERY FROM A WELL-KNOWN AND REPUTABLE BRAND.
CONNECTING TO THE BATTERY
Do not connect the AC power plug until all other connec-
tions are made. Identify the correct polarity of the battery
terminals on the battery. The positive battery terminal is
typically marked by these letters or symbol (POS,P,+).
The negative battery terminal is typically marked by
these letters or symbol (NEG,N,-). Do not make any
connections to the carburetor, fuel lines, or thin, sheet
metal parts. The below instructions are for a negative
ground system (most common). If your vehicle is a pos-
itive ground system (very uncommon), follow the below
instructions in reverse order.
1.) Connect the positive (orange) battery clamp or eye-
let terminal connector to the positive (POS,P,+) battery
terminal.
2.) Connect the negative (black) battery clamp or eyelet
terminal connector to the negative (NEG,N,-) battery ter-
minal or vehicle chassis.
3.) Connect the battery charger's AC power plug into a
suitable electrical outlet. Do not face the battery when
making this connection.
4.) When disconnecting the battery charger, disconnect
in the reverse sequence, removing the negative first (or
positive first for positive ground systems).
BEGIN CHARGING
1.) Verify the voltage and chemistry of the battery.
2.) Confirm that you have connected the battery clamps
or eyelet terminal connectors properly and the AC power
plug is plugged into an electrical outlet.
3.) The charger will begin in Standby mode, indicated by
an orange LED. In Standby, the charger is not providing
any power.
4.) Press the mode button to toggle to the appropriate
charge mode (press and hold for three seconds to enter
an advanced charge mode) for the voltage and chemis-
try of your battery.
5.) The mode LED will illuminate the selected charge
mode and the Charge LEDs will illuminate (depending on
the health of the battery) indicating the charging process
has started.
6.) The charger can now be left connected to the battery
at all times to provide maintenance charging.