Power Attic Ventilator
MODEL: RF-69NR, RF-68HRPSC
IMPORTANT SAFETY INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE. ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
A. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
B. Before servicing or cleaning unit, switch power off at
service panel and lock service panel to prevent power from
being switched on accidentally.
When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag, to
the service panel.
CAUTION:
For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
CAUTION:
This unit has an unguarded impeller. Do not use in
locations readily accessible to people or animals.
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
A. Installation work and electrical wiring must be done by
qualified person(s)
in accordance with all applicable codes and standards,
including fire-rated construction.
B. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent back drafting. Follow
the heating equipment manufacturer's guideline and
safety standards such as those published by the
National Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration, and Air
Conditioning Engineers (ASHRAE), and the local code
authorities.
C. When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
D. Ducted fans must always be vented to the outdoors.
E. If this unit is to be installed over a tub or shower, it
must be marked as appropriate for the application.
F. NEVER place a switch where it can be reached from
a tub or shower.
®
READ & SAVE THESE INSTRUCTIONS!
IMPORTANT: For every 300 CFM of fan performance, a
minimum of one square foot of inlet space in attic or crawl
space is necessary for proper operation. Inlet areas should
be located as far from fan location as possible, such as in
the eave or side walls.
MOUNTING THE FAN
IMPORTANT: If the fan will be mounted on a flat roof, make
a curb on which to mount the fan; the fan must be above
the level of the roof's water line.
1. Determine location of fan (center of attic near roof peak).
At desired location, drill a hole through the roof (centered
between the rafters).
2. Using the drilled hole as a center, make a 14
circle on the roof. To make a circle, a compass can be
made of a scrap piece of wood with two nails placed 7
apart.
3. Make cutout in roof along the circle that has been made.
If the roof is shingled, cut shingles along the circle using
the tin snips, knife etc.
4. Place fan over opening in roof. Nail mounting flange to
roof. Caulk around mounting flange to help prevent water
seepage. If the roof is shingled, slide mounting flange
under the surrounding shingles.
MOUNTING THE THERMOSTAT'S OUTLET BOX
IMPORTANT: Do not mount outlet box near heat source.
1. Mount the outlet box to a nearby rafter so that the outlet
box is higher than the fan motor.
BLACK LEAD
FROM MOTOR
SUPPLY
GROUND
FAN MOTOR
WIRING
INSTALLATION INSTRUCTIONS
1
BLACK LEAD
HOUSE SUPPLY
HOUSE SUPPLY
WHITE LEADS
FROM MOTOR
AND HOUSE
SUPPLY
" diameter
2
1
"
4
WIRING

Publicidad

loading

Resumen de contenidos para NuTone RF-69NR

  • Página 1 ® READ & SAVE THESE INSTRUCTIONS! INSTALLATION INSTRUCTIONS Power Attic Ventilator MODEL: RF-69NR, RF-68HRPSC IMPORTANT SAFETY INSTRUCTIONS IMPORTANT: For every 300 CFM of fan performance, a minimum of one square foot of inlet space in attic or crawl WARNING: TO REDUCE THE RISK OF FIRE. ELECTRIC space is necessary for proper operation.
  • Página 2: Optional Accessory

    WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one year period, NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES, FILTERS, DUCT, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING.
  • Página 3: Importantes Directives De Sécurité

    ® LIRE ET CONSERVER CES DIRECTIVES DIRECTIVES D’INSTALLATION Ventilateur avec moteur pour grenier RF-69NR, RF-68HRPSC MODÈLE: IMPORTANTES DIRECTIVES DE SÉCURITÉ F. Ne placez JAMAIS un interrupteur à la portée d’une personne qui se trouverait dans le bain ou dans la douche.
  • Página 4: Réglage Du Thermostat

    MARCHANDIBILITÉ OU D'ADAPTATION À UN USAGE PARTICULIER. Pendant cette période d’un an, NuTone procédera au remplacement ou à la réparation sans aucuns frais, mais à sa propre discrétion, de tout produit ou pièce jugé défectueux dans le cadre d'une utilisation normale. CETTE GARANTIE NE VISE PAS LES DISPOSITIFS D'AMORÇAGE NI LES TUBES DES LUMINAIRES FLUORESCENTS. Cette garantie ne couvre pas (a) l'entretien et le service courants ni (b) les produits et les pièces ayant fait l'objet d'un usage abusif, de négligence, d'un accident, d'un entretien ou d'une réparation non...
  • Página 5 ® LEA Y GUARDE ESTAS INSTRUCCIONES! INSTRUCCIONES DE INSTALACION Ventilador eléctrico para el desván MODELO: RF-69NR, RF-68HRPSC INSTRUCCIONES IMPORTANTES MONTAJE DEL VENTILADOR IMPORTANTE: Si se va a montar el ventilador en un tejado plano, DE SEGURIDAD haga un bordillo para montar el ventilador; el ventilador debe estar ADVERTENCIA: PARA REDUCIR EL RIESGO DE INCENDIO, sobre el nivel de la red de distribución del agua del tejado.
  • Página 6: Ajuste Del Termostato

    NO LIMITADAS A, GARANTÍAS NO EXPRESADAS DE MERCANTIBILIDAD O ADAPTABLES A UN PROPÓSITO EN PARTICULAR. Durante este período de un año, NuTone reparará o reemplazará a su opción y sin costo, cualquier producto o parte que se encuentre defectuoso bajo condiciones normales de uso y servicio.
  • Página 7: Parts List

    RF-69NR 67174-000 67547 BIRD GUARD RF-68HRPSC 67547-000 87439 MOTOR RF-69NR 87439-000 87405 MOTOR RF-68HRPSC 87405-000 0419B CAPACITOR 7.5µƒ RF-68HRPSC, RF-69NR 0419B-000 87401 BLADE RF-69NR 87401-000 87402 BLADE RF-68HRPSC 87402-000 87409 CONDUIT RF-69NR, RF-68HRPSC 87409-000 86898 MOTOR MOUNTING BRACKET RF-69NR, RF-68HRPSC...

Este manual también es adecuado para:

Rf-68hrpsc