Power Attic Ventilator
MODEL: RF-49 Series
IMPORTANT SAFETY INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
A. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer.
B. Before servicing or cleaning unit, switch power off at service panel
and lock service panel to prevent power from being switched on
accidentally.
When the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the service
panel.
CAUTION:
For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.
CAUTION:
This unit has an unguarded impeller. Do not use in locations
readily accessible to people or animals.
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
A. Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction.
B. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to
prevent back drafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA), and
the American Society for Heating, Refrigeration, and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
C. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
D. Ducted fans must always be vented to the outdoors.
E. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application.
F. NEVER place a switch where it can be reached from a tub or
shower.
IMPORTANT: For every 300 CFM of fan performance, a minimum
of one square foot of inlet space in attic or crawl space is
necessary for proper operation. Inlet areas should be located as far
from fan location as possible, such as in the eave or side walls.
MOUNTING THE FAN
IMPORTANT: If the fan will be mounted on a flat roof, make a curb
on which to mount the fan; the fan must be above the level of the
roof's water line.
READ & SAVE THESE INSTRUCTIONS!
INSTALLATION INSTRUCTIONS
1. Determine the location of the fan. Place the unit on top of the
shingles as close to the center of the roof as possible and near the
ridgeline. For best appearance, the unit should be mounted on the
back side of the house and should be visible only on one side of
the roof. This will require that the unit be moved down slightly from
the ridgeline.
2. When the desired location is established, locate a center line
between two rafters and drill a small hole through the roof from the
inside. This hole will be used as a center for the following
operations.
3. Draw a reference square on 25
drilled hole as a center. Within the square, draw a 17
circle. Cut and remove the shingles, nails and felt within this circle.
Draw and cut a 14
7
" diameter hole through the decking.
8
4. With the lettering of the unit parallel to the ridgeline, slide the top
flange of the unit up under the shingles (some roofing nails may
need to be removed). Position the unit on the reference square
previously drawn to align the exhaust openings. With the unit
located, apply a generous amount of roofing compound between
the flange and shingles approximately 1" in from perimeter of
flange. Secure with galvanized roofing nails. Follow the nailing
pattern shown.
MOUNTING THE THERMOSTAT/
OUTLET BOX
IMPORTANT: Do not mount outlet box near heat source.
1. Mount the outlet box to a nearby rafter so that the outlet box is
higher that the fan motor.
BLACK LEAD
FROM MOTOR
SUPPLY
GROUND
FAN MOTOR
WIRING
FLEXIBLE CONDUIT
SERVES AS GROUND
" by 25
" on the roof using the
3
3
8
8
3
" diameter
8
BLACK LEAD FROM
HOUSE SUPPLY
HOUSE SUPPLY
WIRING
WHITE LEADS
FROM MOTOR
AND HOUSE
SUPPLY

Publicidad

Tabla de contenido
loading

Resumen de contenidos para NuTone RF-49 Serie

  • Página 1 READ & SAVE THESE INSTRUCTIONS! INSTALLATION INSTRUCTIONS Power Attic Ventilator MODEL: RF-49 Series IMPORTANT SAFETY INSTRUCTIONS 1. Determine the location of the fan. Place the unit on top of the shingles as close to the center of the roof as possible and near the WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC ridgeline.
  • Página 2: Optional Accessory

    WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one year period, NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES, FILTERS, DUCT, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING.
  • Página 3: Importantes Directives De Sécuirité

    LIRE ET CONSERVER CES DIRECTIVES DIRECTIVES D’INSTALLATION Ventilateur avec moteur pour grenier MODÈLE: RF-49 Serie 1. Déterminez l'emplacement du ventilateur. Placez l'appareil sur les IMPORTANTES DIRECTIVES DE SÉCUIRITÉ bardeaux, le plus près possible du centre et du faîte du toit. Pour ADVERTISSEMENT - POUR RÉDUIRE LES RISQUES...
  • Página 4: Réglage Du Thermostat

    MARCHANDIBILITÉ OU D'ADAPTATION À UN USAGE PARTICULIER. Pendant cette période d’un an, NuTone procédera au remplacement ou à la réparation sans aucuns frais, mais à sa propre discrétion, de tout produit ou pièce jugé défectueux dans le cadre d'une utilisation normale. CETTE GARANTIE NE VISE PAS LES DISPOSITIFS D'AMORÇAGE NI LES TUBES DES LUMINAIRES FLUORESCENTS. Cette garantie ne couvre pas (a) l'entretien et le service courants ni (b) les produits et les pièces ayant fait l'objet d'un usage abusif, de négligence, d'un accident, d'un entretien ou d'une réparation non...
  • Página 5: Ventilador Eléctrico Para El Desván

    LEA Y GUARDE ESTAS INSTRUCCIONES! INSTRUCCIONES DE INSTALACION Ventilador eléctrico para el desván MODELO: RF-49 Series 1. Determine la ubicación del ventilador. Coloque la unidad arriba INSTRUCCIONES IMPORTANTES de los tablones tan cerca como sea posible del centro del tejado DE SEGURIDAD y del caballete.
  • Página 6: Ajuste Del Termostato

    NO LIMITADAS A, GARANTÍAS NO EXPRESADAS DE MERCANTIBILIDAD O ADAPTABLES A UN PROPÓSITO EN PARTICULAR. Durante este período de un año, NuTone reparará o reemplazará a su opción y sin costo, cualquier producto o parte que se encuentre defectuoso bajo condiciones normales de uso y servicio.
  • Página 7: Parts List

    RF-49RP, RF-49AM, RF-WG, RF-BR 0710B-000 0711B OUTLET BOX THERMOSTAT ASSY RF-49RP, RF-49AM, RF-WG, RF-BR 0711B-000 NOTE: Always order by current part number RF-49 Series I.I. NuTone Attn: Parts Department 4820 Red Bank Road Cincinnati, OH 45227-1599 Phone: (513) 527-5426 Fax: (513) 527-5173...

Tabla de contenido