Description And Specifications; Engineering Data; Piping; Wiring And Grounding - Xylem REDJACKET MCB Instrucciones De Instalación, Funcionamiento Y Mantenimiento

Bombas portátiles
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Description and Specifications

Description and Specifications
This is a portable horizontal multi-stage pump designed
for residential and agricultural washdown, misting and
general boosting services.
The 304 stainless steel version is used for HVAC, general
commercial, reverse osmosis and filtration applications.

Engineering Data

Engineering Data
Maximum Liquid Temperatures: 160°F (72°C).
Maximum Suction Pressure 75 psi.
Pipe connections are 1" NPT suction and discharge.
3 ⁄ 4 " Hose Adapters are available.
Capacities to 33 GPM.
Heads to 600 Feet (260) psi.
Rotation: Right hand, ie; clockwise when viewed from
motor end.

Piping

Piping
Piping should be no smaller than the pump discharge
and/or suction connections. Piping should be kept as
short as possible, avoiding unnecessary fittings to mini-
mize friction losses.
All piping MUST be independently supported and
MUST NOT place any piping loads on the pump.
All joints MUST be airtight. Use 3 – 4 wraps of Tef-
lon™ tape to seal threaded connections.

Wiring and Grounding

Wiring and Grounding
Install ground and wire according to
WARNING
local and National Electrical Code
requirements.
Install an all leg disconnect switch
near the pump.
Disconnect and lockout electrical
supply before installing or servicing
Hazardous voltage
can shock, burn or
pump.
cause death.
Electrical supply MUST match pump's name plate
specifications. Incorrect voltage can cause fire and/or
damage to the motor and voids warranty.
Motors not protected MUST be provided with con-
tactors and thermal overloads on single phase mo-
tors, or starters with heaters on three phase motors.
See motor nameplate.
Use only stranded copper wire to motor and ground.
The ground wire MUST be at least as large as the wire
to the motor. Wires should be color coded for ease of

maintenance.

Pumps with open spray application must
WARNING
be plugged into electrical service which is
protected by a Ground Fault Service Interrupter. Failure
to do so may result in serious personal injury or death
and property damage.
Follow motor manufacturer's wiring diagram on the
motor nameplate or terminal cover carefully.
FAILURE TO PERMANENTLY
WARNING
GROUND THE PUMP, MOTOR AND
Hazardous
CONTROLS BEFORE CONNECTING
voltage
TO ELECTRICAL POWER CAN
CAUSE SHOCK, BURNS OR DEATH.

Rotation

Rotation
NOTICE: INCORRECT ROTATION MAY CAUSE
DAMAGE TO PUMP AND VOIDS THE
WARRANTY.
Correct rotation is right-hand, CLOCKWISE when
viewed from the motor end.
To reverse three phase motor rotation interchange any
two power supply leads.

Operation

Operation
SPLASHING OR IMMERSING OPEN
WARNING
DRIP PROOF MOTORS IN FLUIDS
Hazardous
CAN SHORT OUT MOTOR AND
voltage
CAUSE FIRE, SHOCK, BURNS OR
DEATH.
NOTICE: PUMP MUST BE FULLY PRIMED BEFORE
OPERATION. DO NOT RUN PUMP DRY.
After stabilizing the system at normal operating condi-
tions, check the piping. If necessary, adjust the pipe
supports.
Do not run pump dry; damage to me-
CAUTION
chanical seal will result. Do not run against
closed nozzle for prolonged periods or damage to pump
and piping will result.
Handle Assembly
Remove two top bolts from motor adapter. Insert them
through handle back into the motor adapter and tighten
securely.
Nozzling
It is important to choose the right nozzle for proper
pump performance. The faucet supplying the water to
the pump should be checked to see what rate of flow it
will furnish. If the one min. flow with the faucet open is:
7 gals. — Use 6 gpm nozzle V2005
(which is included with each AM2)
6 gals. — Use 5 gpm nozzle V1502
5 gals. — Use 4 gpm nozzle SN0045
4 gals. — Use 3 gpm nozzle V10152
By using this method of choosing nozzles we can keep a
positive pressure at the pump intake. This will keep the
pump from "robbing" water from other faucets.
Dairy Farm Use
We recommend that all WaterGuns ® used on farms
producing Grade "A'' milk be equipped with a Vacuum
Breaker, installed according to instructions supplied with
Vacuum Breaker. This prevents sub-atmospheric pres-
sure in the supply line even if the water supply should
diminish. We suggest the WaterGun be hung on a wall at
least 18" off the floor and that a hose rack be provided to
store the discharge hose off the floor.
Maintenance
Maintenance
FAILURE TO DISCONNECT AND
WARNING
LOCKOUT ELECTRICAL POWER
Hazardous
BEFORE ATTEMPTING ANY
voltage
MAINTENANCE CAN CAUSE SHOCK,
BURNS OR DEATH.
AM 7 Kit