OPERATOR
Operator Menu Tree Guide
MENU TREE
(Press MENU SELECT Button)
POOL
IDLE/HEAT/COOL
SET=__
ACT=__
SPA
IDLE/HEAT/COOL
SET=__
ACT=__
HEAT / COOL / AUTO
SET TO - H/C/A
HEAT PUMP RUNTIME
REMAINING = NONE
REMOTE MODE
OFF/RELAY/RS-485
AUTOSET
HEAT/COOL/AUTO
OVERRIDE IS ON/OFF
EXTEND
HEAT/COOL/AUTO
OVERRIDE IS ON/OFF
RESTART / PUMP START /
SENSING WATER TEMP
DELAYS
SUCTION TEMP
ACTUAL = ___
ALARM STATUS
HEAT/COOL/AUTO MODE
POOL/SPA
*
Menu appears only if Heat and Cool mode is enabled
at the factory.
**
Menu appears only if AutoSet or Extend is enabled in the
Service menu.
***
Menu appears only if a delay is active.
****
Menu appears only if Defrost is enabled in the Service menu.
Navigating the Operator Menu Screens
Press the MENU SELECT button to view each screen. While in
the menu screens, if no activity is detected after 15 seconds, the
main screen is displayed.
1. Pool and Spa Run Screens
Displays whether the heat pump is idle, heating or cooling and if
the Pool or Spa set point is active. Displays the water temperature
set point and the actual measured water temperature.
*
2. Heat or Cool Mode Selection Screen
This screen is only shown on Heat-and-Cool heat pumps. This
screen allows the operator to switch the heat pump between
Heat-only, Cool-only and Auto Heat/Cool modes.
3. Heat Pump Timer Screen
*
This feature is an adjustable timer to allow the heat pump to run
(green light ON) for a predetermined amount of time and then turn
OFF (green light OFF).
4. Remote Mode Screen
Allows the operator to select the Remote mode, Off, Relay or RS-
485 (serial). In RS-485 Remote mode, the heat pump is controlled
by an automation controller. The local Pool and Spa set points are
not active (displayed as "N/A") in this mode.
5. AutoSet On/Off Screen
**
This screen is only shown if the AutoSet mode is enabled in the
Service Menu Tree; it allows the operator to turn the AutoSet mode
On and Off. AutoSet mode energizes a contactor for one cycle and
**
starts a remote filter pump which allows the heat pump to heat or
cool the water as necessary.
**
6. Extend On/Off Screen
This screen is only shown if the Extend mode is enabled in the
**
Service Menu Tree; it allows the operator to turn the Extend mode
On and Off. Extend mode energizes a contactor for one cycle and
starts a remote filter pump which allows the heat pump to heat or
cool the water as necessary.
***
***
7. Time Delay Screen
If the heat pump is waiting on any restart, pump start, or sensing
water temperature delays, this screen shows how much delay
time is left.
****
8. Suction Temperature Screen
****
Shows the suction line temperature of the refrigerant. This screen
appears if the Defrost is enabled.
9. Alarm Screen
Shows if an alarm condition is present. If no alarms are present
the screen will display ALARM STATUS NONE. The control board
has the ability to store a 30 Alarm history of previous alarms that
have occurred. At the alarm status screen, press the DOWN arrow.
The first alarm will be the most recent alarm that has occurred.
Successive presses (up to 30) of the DOWN arrow will display the
alarm history in the order of occurrence. The operator can scroll
back up using the UP button. There is an option to erase the history.
10. Operation Mode Screen
Displays whether the heat pump is in Heat, Cool or Auto mode.
It also displays whether the Pool or Spa set point is active. The
active set point can be switched between Pool and Spa by using
the UP and DOWN arrows.
ULTRATEMP
Heat Pump Installation and User' s Guide
®
17