Service Menu Tree Guide

SERVICE
MENU TREE
(Press UP and DOWN Arrows Simultaneously)
LANGUAGE - IDIOMA - LANGUE
ENGLISH / ESPANOL / FRANCAIS
SOFTWARE VERSION
REV. ____
INTELL ADDRESS
ADDRESS = 1-16
PUMP START TIME
TIME = 1 - 4 HRS
PUMP START DELAY
TIME = 0 - 5 MINS
TEMPERATURE SCALE
FAHRENHEIT / CELSIUS
WATER TEMP OFFSET
OFFSET = -2 TO +2
DEFROST
ENABLE / DISABLE
AUTOSET
ENABLE / DISABLE
EXTEND
ENABLE / DISABLE
WF HP LP PL SP
1
1
1
0
FAN COMP PMP REV
1
1
1
TEMP. RECORD
HOUR # ___
___°F
RUN TIMES/COUNTS
PRESS POOL/SPA
TO EXIT SETUP
**
Menu appears only if AutoSet or Extend is enabled in the
Service menu.
INPUT STATUS
WF = WATER FLOW SWITCH
HP = HIGH REFRIGERANT PRESSURE SWITCH
LP - LOW REFRIGERANT PRESSURE SWITCH
PL - POOL REMOTE
SP - SPA REMOTE
The number one (1) is
††
OUTPUT STATUS
displayed when the
FAN - FAN
associated input/output is
COMP - COMPRESSOR
ON and zero (0) is displayed
PMP - FILTER PUMP
REV - REVERSING VALVE
when input/output is OFF.
**
**
0
††
0
††
Navigating the Service Menu Screens
Press the UP and DOWN arrows simultaneously. If no activity is
detected after 15 seconds, the display will return to the main screen.
1. Language Selection
Displays the language selected. Select either English, Spanish
or French using the UP and DOWN arrows.
2. Software Revision
Displays the software revision level loaded on the control board.
3. Intell Address
Heat Pump RS-485 Communications Address which must
match the address used in the IntelliTouch or EasyTouch
automation controller being communicated with. Adjustable
from 1 to 16 using the UP and DOWN arrows.
4. Pump Start Time
This displays the period at which the heat pump will close the
AutoSet contactor to start the filter pump. Adjustable from 1 to
4 hours using the UP and DOWN arrows.
5. Pump Start Delay
Displays the time period between heat pump start cycles.
Adjustable from 0 to 5 minutes using the UP and Down arrows.
6. Temperature Scale
Determines if the water temperature actual reading and set
point is displayed in degrees Fahrenheit or Celsius. Adjusted
between Fahrenheit and Celsius using the UP and DOWN
arrows.
7. Temp Offset
Adjusts the measured water temperature up or down to allow
the operator to match the heat pump's displayed temperature
to a remote temperature monitoring device. The offset can be
varied from -2 to +2 using the UP and DOWN arrows.
8. Defrost Screen
Allows the user to Enable/Disable Defrost feature.
9. AutoSet Screen
Allows the user to Enable/Disable AutoSet feature.
10. Extend Screen
Allows the user to Enable/Disable Extend feature.
11. Input Screen and Output Screen
The Input and Output screens are diagnostic displays which
show the status of the input sensors and output devices. The
number one (1) is displayed when the associated input/output
is on and zero (0) is displayed when the associated input/
output is off.
12. Temperature Log and Run Time Counters
These screens display a list of compressor, fan and valve
run times, and a history of measured water temperatures.
This information is provided so the user can easily track
performance and troubleshoot issues.
13. Exit Set Up
Pressing the POOL/SPA button while this screen is displayed
returns the display to the Pool or Spa Run Screen as
appropriate.