8.3- Modification of the rotation direction (in user mode):
1
5s
9
Cancelling programming
9.1- Switch off the power supply to the motor for 2 seconds.
9.2- Switch the power to the motor back on for 7 seconds.
9.3- Switch off the power supply to the motor for 2 seconds.
9.4- Switch the power to the motor back on.
- If the motor is on the end limit position (up or down), the motor
will run briefly in one direction and then in the other, otherwise,
the motor runs for 5 seconds in random direction.
The motor is now in the "cancelling" mode".
If you switch off the power to several motors, they will all be in cancelling mode. That is why, you
must "eject" out of this mode all the motors that are not to be deprogrammed by sending a command
from their individual control transmitter (UP or Down).
9.5- Then, confirm the cancelling of the concerned motor from the individual control:
- Press the PROG key of the transmitter more than 7 seconds. Maintain the
pressure until the motor will first run for 0,5 second in one direction and
then in the other, and a few second later, it will run again in both direction.
The T5EHz motor is now as it was originally configured, and no trans-
mitter and no settings is saved in its memory and is ready for a new
programming.
10
Operation and maintenance
- This drive is maintenance-free.
- Press the ▲ button on the control point to raise the motorised product.
- Press the ▼ button on the control point to lower the motorised product.
- If the motorised product is moving, briefly press the "Stop" button, the motorised product stop automatically.
- The motorised product is then stopped, briefly press the "Stop" button, the motorised product moves to the
programmed intermediate position. (To modify or delete an intermediate position, see the section §7).
Tips and recommendations for use:
PROBLEMS
The motorised product does not operate. The overheating protection on the drive has been activated.
If the motorised product still does not work, contact a drive and home automation professional.
SIMU SAS, F-70103 as manufacturer hereby declares that the drive covered by these instructions when marked for input voltage 230V~50Hz and used
as intended according to these instructions, is in compliance with the essential requirements of the applicable European Directives and in particular of the
Machinery Directive 2006/42/EC, and the Radio Directive 2014/53/EU. The full text of the EU declaration of conformity is available at www.simu.com.
Emmanuel CARMIER, general director, GRAY, 10/2016.
2
Do not move the roller shutter to the up or down end limit position.
1 - Press the Up and Down buttons simultaneously for 5 seconds. The motor runs
briefly in one direction, then in the other.
2 - Within 2 seconds, press the Stop button for 2 seconds. The motor briefly runs in
2s
one direction, then in the other. The rotation direction has been changed.
2s
OFF
9.1
2s
POSSIBLE CAUSES
ON
OFF
9.2
7s
9.3
2s
9.4
PROG
2s
>7s
SOLUTIONS
Wait for the drive to cool down.
ON
5s
7s
5/5