3 - Selected parameter adjustment
The adjustment starts from the actual value.
a - Keep joystick in neutral position.
b - Parameter value adjustment:
Single push P4 to decrease 10 units.
Single push P5 to increase 10 units.
Single push P3 to decrease 1 unit.
Single push P2 to increase 1 unit.
(see the illustration).
L1 keeps flashing steadily.
L2 flashes according to the parameter value.
At 0 L2 is off. An increased value will intensify the flashing.
The maximum value is 255. At this value the leds flash
synchronously.
c - Move the joystick in the related adjusted direction to
verify the effects of the new setting on the machine.
If the movement of the machine is not satisfactory, restart
#a
from
until a correct adjustment has been found.
4 - Parameter value saving
To save the adjustment and quit the
programming mode, push P4 and P5 at the
same time with the joystick in neutral position
(see the illustration).
L1 and L2 turn off.
+10
- 8 -
+1
-1
-10
P5
P4