Warning! :
Problems and failures may occur even when the appliance is used properly. Here is
a list of the mist probably situations and controls that the operator should perform
to avoid applying to a service centre unnecessarily.
If the problem is not solved after the necessary controls, turn off the appliance
immediately, unplug it, cut off any supplies and apply to a service centre.
DISPLAY MSG
DEFECT/ANOMALY
THE KEYPAD DOES
NOT START
THE VATT MOVEMENT IS
NOT POSSIBLE
THE HEATING SYSTEM
DOESN'T WORK
Instruction manual for installation and maintenance
Electric Tilting Cooker
HOW TO PROCEED IF ...
DESCRIPTION
Intervention of the safety thermostat:
apply to a service centre for assistance.
Overheating in the relay card.
Automatic intervention to save the appliance electric circuit.
The alarm stops automatically when the electric circuit temperature
return into the values pre-established (< 60° C).
Anomaly in the ventilation system:
Apply to a service centre for assistance.
Damaged temperature probe (message flashing):
Apply to a service centre for assistance.
Error in connection between relay Board and the keyboard tab.
(The possible presence of moisture in the relay Board):
apply to a service centre for technical assistance.
OPERATION
Verify any cut-off on the electric feed (main switch of the
electrical net).
Verify any accidental pressing of the emergency button,
otherwise:
Apply to a service centre for assistance.
Apply to a service centre for assistance.
Verify that the vat must be in cooking position.
The led of the key
Apply to a service centre for assistance.
CBRE40
must be switched off otherwise:
GB-CBRE40-DU-00 Page
10 di 10