Delabie TEMPOMIX DEL 790000 Manual De Instrucciones página 6

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 18
OPERATION
• Press the push-button control to open the valve.
• Rotate the push-button control to select the desired temperature.
• Automatic shut-off after ~20 seconds for washbasins and ~30 seconds for showers (+5/-10 at 3 bar,
according to the European Standard EN 816).
INSTALLATION
• Under no circumstances should the non-return valves a (figs. A, B) be removed from the water inlets.
• Install the filter joints b (figs. A, B) supplied exactly as shown in the diagram. They will protect
the non-return valves from damage and hold them in place.
• Supply with cold water and hot water at a maximum temperature of 60°C, and balance the pressure
between the hot and cold water (∆P < 1 bar). Ensure that hot water is always delivered from
the left side and cold from the right. Maximum supply pressure is 10 bar (we recommend 1 to 5 bar
dynamic pressure). Take care not to pinch the PEX flexibles (fig. D).
Washbasins
• Use the DELABIE elbow connectors ref. 836020 or 838020 for installations with 150mm centres.
Deck-mounted Washbasins
• Diamètre de perçage 34 mm.
• Mount the body of the mixer on the washbasin and tighten the nuts c (fig. A) on the fixing plate.
• Ensure a waterproof seal between the mixer and the work plan that is appropriate for the type of installation.
Recessed Showers (fig. C)
• The wall mounting area should measure: W. 130mm x H. 110mm, with an adjustable depth of 55-75mm.
• Attach the connectors d to the recessing box e using the back-nuts f and position the mixer
at the desired height.
• Remove the mixer. Weld/solder the cold water inlet, hot water inlet and mixed water outlet
to the Ø14 or Ø15 copper tubes, depending on the model.
• Seal the boxed unit e and welded/soldered joints.
• Connect the mixer to the connectors d with F¾" nuts.
• Position the wall plate against the wall using the self-adhesive foam seal, with the vent/drain at the bottom:
- Tighten the Ø195 wall plate with the screw g using a 2.5mm Allen key;
- Or tighten the 160 x 160mm or 300 x 300mm wall plate with the 4 screws (4 x 35) supplied.
• For stainless steel wall plate version: position the silicone washer behind the wall plate to ensure
a water tight seal between the wall plate and the wall. Leave a vent/drain at the bottom to allow
any residual water to drain away.
THE INSTALLER MUST ENSURE THAT:
• THE SEAL AROUND THE RECESSING HOUSING IS WATERPROOF TO PREVENT ANY INGRESS
OF WATER;
• ANY WATER ACCIDENTALLY ENTERING THE RECESSING HOUSING (E.G. CONDENSATION,
RUN OFF, LEAKS, ETC.) HAS A DRAINAGE POINT TO PREVENT ANY STAGNATION;
• THE INTEGRITY OF THE SEALS BETWEEN THE STAINLESS STEEL WALL PLATE AND THE WALL
OR THE WALL PLATE AND THE MIXER/TAP/VALVE AT LEAST ONCE A YEAR, AND MAKE GOOD
IF NECESSARY.
If this advice is not followed, water may leak into the wall.
DELABIE cannot be held responsible for any ingress.
FOR FURTHER INFORMATION PLEASE CALL DELABIE TECHNICAL SUPPORT
UK: 01491 821821. ALL OTHER MARKETS: +33 (0)3-22-60-22-74.
EN

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Tempomix del 798152Tempomix 184147Tempomix 184148

Tabla de contenido