Notes on connecting and installation
Warning
Switch off the power supply before carrying out any
assembly, installation or maintenance work.
Warning
If an axis is fitted in a sloping or vertical position, the
work load may slide down.
S Check whether external safety measures are neces−
sary (e.g. toothed latches or moveable bolts).
This prevents the work load sliding down suddenly if
there is a power failure.
Power supply
**)
Load supply
Nominal current (max. permanent
current)
Peak current
**)
Logic supply
Nominal current/peak current
Internal fuse
I/O supply (only SFC−LAC−...−IO)
Nominal current/peak current
(max. 0.5 A per output)
*)
The tolerances for power supply must strictly comply with
the SFC−LAC connections.
**)
Connect grounds for equal reference potential!
Festo P.BE−K−SFC−LAC 0707a English
*)
Value
48 VDC +5 %/−10 %
10 A
20 A
24 VDC ±10 %
0.4 A/0.8 A
2.5 A super−fast
24 VDC ±10 %
0.05 A/2.1 A