GB
TECHNICAL SPECIFICATIONS
Motor power supply
Max. door surface area
Opening time
Max. absorbed current (at 230Vac)
Max. motor absorbed current (at 24V)
Operating temperature
Protection rating
Built-in control unit
Useful travel
Max. thrust
Encoder
Guide length
Battery charger
Courtesy light
Work intermittence
* with optional ZENGB4: 3902 mm
** with optional ZENGB4: Max 4240 mm
PRELIMINARY CHECKS
Before proceeding with installation, the following checks/procedures should be performed.
1) Carefully read the instructions, observing the sequence of each assembly phase.
2) The device must not be operated in environments where there is any flammable gas/liquid.
3) The door structure (sectional/up-and-over) must be solid and suited to the installation.
4) The door must move smoothly throughout travel with no points or friction or vibrations.
5) The door must open and close exclusively under the traction/thrust force (with no upturning or rotation).
6) Remove the locking bolt on door closure.
OVERALL DIMENSIONS
ZEN 60
24 Vdc
9 m
2
20 sec
0.5 A
5 A
-10 +70°C
IP 30
Z124
2842 mm*
600 N
Yes
3200 mm**
optional
10W Halogen
80%
ZEN 100
24 Vdc
12 m
2
20 sec
0.5 A
5 A
-10 +70°C
IP 30
Z124
2842 mm*
1000 N
Yes
3200 mm**
optional
10W Halogen
80%
Fig. 17
51