Descargar Imprimir esta página

Special Functions - Telcoma Automations ZEN 100E Manual Del Usuario

Automatismo para puertas seccionales y basculantes

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 34
GB
Advanced programming - Dipswitch 6 and Dipswitch 9 in ON position
Programmable pause time and deceleration during closure
1) Hold down the STOP/PROG button for about 5 seconds until LED LD1 lights up.
2) Press the PP button: the motor will open as far as the opening stop – FIG. 2A.
3) Wait for the required pause interval, then press PP again: the motor now performs the closure movement.
4) Press PP when you want deceleration to begin: the motor will now decelerate.
5) The motor moves to the closure stop position – FIG. 1A.
6) The motor now performs a complete test cycle (opening and closure).
NOTE: If you wish to set the closure point manually (point 5), remove the stop FIG. 1A and press the PP button on reaching
the desired closure position.

Special functions

If the closure position is not as required, a precision adjustment can be made:
1) With the door closed, set dipswitch 8 to the ON position: LED LD1 will begin flashing.
2) Press the STOP/PROG button to close the door by a few mm.
3) Press the PP button to open the door by a few mm.
4) Return dipswitch 8 to the OFF position
5) Perform a manoeuvre and check the closure position.
61

Publicidad

loading

Este manual también es adecuado para:

Zen 60eZen 100Zen 60