Safety Considerations; Technical Data - Dustcontrol DC 2800c Manual De Instrucciones

Ocultar thumbs Ver también para DC 2800c:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 25

Safety Considerations

Read all instructions before attempting to operate this
machine and save these instructions.
Warning! When using electric machines, basic safety
precautions should always be
risk of fi re, electric shock and personal injury, including
the following:
1.
Work area environment
Don´t expose the machine for rain. Don´t use it in
damp or wet locations or in presence of fl ammable
liquids or gases.
2. Overload
Never let the machine operate fully throttled. Always
follow the regulations pertinent to the material you
are working with ie asbestos. Don´t use the machine
for purposes that it isn´t
3.
Body injuries
Never let the suction come in contact with parts
of the body. Th e strong suction eff ect can hurt the
blood-vessels in the skin. Don't repair the electric
components yourself, get some-body qualifi ed. Faults
may cause injury. See also below under warnings.
4. Don´t abuse cord
Never pull the machine by cord. Keep cord from
heat and sharp edges. Check the electric cable regu-
larly if damage.

TECHNICAL DATA

HxWxL
Weight
Inlet
Hose length
Collecting sack
Flow, max
Neg. pressure, max
115/230 V
Power consumption
115/230 V
Fine fi lter polyester, area
Degree of separation
fi ne fi lter
EN 60335-2-69, Class M)
Filter area, microfi lter
Degree of separation,
microfi lter
(EN 1822-1)
(EN 60335-2-69, Class H)
Sound level
5.
followed to reduce the
6. Maintain the machine with care
7.
8. Warning
intended for.
1070x420x510 mm
14 kg
φ 50 mm
5 m
20 l
190 m
3
/h
21/24 kPa
1200 W/1400 W
1.5 m
2
99,9 %
2
0.85 m
HEPA H13
99,995 %
< 68 dB(A)
DC 2800c, 9
Important measure
With cleaning and maintenance on the machine,
the power cable should be dis-connected from the
supply.
Keep machine clean and check that the hose is
entired and that all gaskets are tight. Follow instruc-
tions. Keep handles dry and free from oil and grease.
Checking of damage
Before further use of the machine it should be care-
fully checked that the machine is undamaged. If
there are any damaged parts these should be repaired
by of a Dustcontrol authorized service centre.
Use only accessories and replaceable parts which are
available in Dustcontrol catalogue.
Vacuum producer
capacity
kPa
20
1400 w
15
1200 w
10
5
0
50 100 150 200 m
3
/h
Part No 94112

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

94112

Tabla de contenido