Unit Adjustments
Top Section Gas Top Pilot Adjustment
Purge all air from supply system by turning on one top
burner valve. Then turn off valve and adjust top pilot
flame using pilot adjusting screw (figure 5) so that flame is
even with top of flash tube. See figure 4. To light the
burner, push and turn top burner knob to the lite position.
TOP OF FLASH TUBE
FIGURE 4
MANIFOLD PIPE
FIGURE 5
Top Section Electric Ignition
To operate, push and turn top burner knob to the
LITE/START position. The top burner will light. To turn
OFF spark after the top burner has ignited turn knob to HI
setting. For ranges with hi-med-warm valves, turn knob,
either direction to HI setting.
Top Burner Adjustment
HI-LOW VALVES:
The approximate height of
the flame at the high or
full-on position is a distinct
inner blue cone of at least
3/4 inch (see figure 7). Turn
valve handle counterclock-
wise 90° to the full ON,
position and adjust air
shutter (figure 8).
YELLOW TIP OF PILOT FLAME
BLUE OF PILOT FLAME
PILOT SHIELD
PILOT FITTING
PILOT ADJUSTING SCREW
NOTE: SOME MODELS HAVE MORE
THAN ONE PILOT ADJUSTMENT
ON THE MANIFOLD PIPE.
FLAME
3/4²
FIGURE 7
Top burner adjustment can be checked as follows:
1. Yellow flame on burner - open burner air shutter to the
widest opening that will not cause the flame to lift or
blow off the burner when cold. (See figure 8).
2. Distinct blue flame but lifting - close burner air shutter
to the point where it will not cause the flame to lift or
blow off the burner when cold. (See figure 8).
NOTE: Correctly adjusted sealed burners, can have
flames that will lift or blow off without a pot over the
burner. These should be adjusted with a pot in place.
AIR
SHUTTER
ORIFICE
HOOD
SEALED BURNERS
Top Burner Adjustment
HI-MED-WARM VALVE:
The burner flame at the WARM
position should extend to the
outer edge of the lip of the
burner cap. The WARM setting
should be such that a stable
flame is maintained on the
burner when turning the knob
from HIGH to WARM. If it
should be necessary to in-
crease or decrease the flame
at the WARM setting, operate burner at HIGH position
for approximately five minutes. Turn knob to WARM
(see figure 9). Remove valve handle and with a small
screwdriver make the desired adjustment by turning
adjustment screw located in center of valve stem. Check
each top burner at the WARM position for flame size.
MED (MEDIUM) is an intermediate setting and there is no
adjustment to be made.
-10-
AIR SHUTTER
FIGURE 8
FIGURE 9
HI-MED-WARM KNOB
ART #9219- - 916