Installation Instructions

Rough-in Installation
Control valve assembly, piping
and fittings
Reference as required:
Visual Guide ...................................1
Dimensions illustration ................4
1)
Determine wall thickness
Determine type of wall and wall
thickness where valve will be
mounted as follows.
Fiber Glass or acrylic walls:
Th ickness =
1/2" (13mm)
Dry wall, plaster, other type
walls:
Th ickness = more than
Skip ahead to step 3
(13mm)
2)
Attach mounting plate
Seat plate against valve assembly.
Figure 1 Mounting plates
when using mounting plate
Protective shield
snap on-off
p/n T-176
p/n T-177
cutout hole size
3-3/4" ( 95 mm) min.
3)
Attach Protective shield
Attach plastic protective shield
by snap fi tting over end of valve
spindle as shown in fi gure 2.
Page
4)
Install control valve
Install through cutout hole in wall
as specifi ed in fi gure 2 below and
Dimension illustration on page 4.
5)
Install piping and fi ttings
Piping and fi ttings not supplied.
Shower head (S on valve)
Pipe from outlet port on valve
or less.
marked
mounting arm location.
Hot & Cold Supply (H & C)
1/2"
Pipe hot water supply to valve
input marked
supply to valve input marked
Tub Spout (T on valve)
Pipe from outlet port on valve
marked
6)
Remove protective shields.
Remove shield snap fi tted over
the end of valve spindle aft er
valve is securely installled
7)
Adjust valve packing nut
Turn hot & cold supplies on.
Valve will not operate unless
Wall thickness
1/16" (2 mm) min.
1/2" (13 mm) max.
finished wall
4" (101 mm) max.
Figure 2 Mounting valve
to shower head
S
and cold water
H
.
C
to tub spout.
T
without mounting plate
Mounting plate,
Ensure plate is
flush against
inner wall
be flush with back
side of this surface
Page 2
both hot and cold water supply
pressure are turned on.
Place handle over end of
spindle stem.
Tighten packing
nut
for
positive
resistance as handle is rotated
from shutoff position across
adjustment range.
packing
nut
control
spindle
stem
Temp.
limit stop
adjust
Figure 3 Limit stop screw
8)
Flush system and check
for leaks
Turn valve to the warm position
and run for a few minutes.
If system is dirty, remove valve
spindle in valve to ensure
proper fl ushing. See service
instructions.
Wall thickness
1/2" (2 mm)
or greater
finished wall
Pipe centerline
to finished wall
2-3/8" ± 1/2"
60 mm ± 13 mm
finished wall must
snap on-off
plaster shield
cutout hole size
3-1/2" ( 89 mm) min.
4" (101 mm) max.
control
frictional
wall