dirna Bergstrom bycool SLIM FIT Diagnosis De Averías página 20

Ocultar thumbs Ver también para bycool SLIM FIT:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 6
SLIM FIT
EN
Symptom
• When the unit starts up or runs, the
display
shows
protection).
The
automatically, with the display showing
E9 until the unit has a slant of less than
45º.
• Water is entering the cabin or is filtering
in from outside.
The equipment works but does not
cool.
* Suitable machinery must be used whenever it is necessary to extract or introduce
the circuit gas load, respecting the environment at all times.
E9
(compressor
unit
goes
off
Air conditioning for vehicles
• Unit or card slant of 45º or over.
• Valves or wastewater pipes obstructed.
• EPDM seal poorly attached or defective.
• The cabling outputs which protrude from
the lower cover of the blower and coil
cabin are not properly sealed.
Too much or too little load in the
circuits.
• Electro wire clamp inverted.
• Dirt in the capacitor.
• Electro defective.
• Blockage in the circuit.
20
Cause