SLIM FIT
EN
VEHICLES WITHOUT ORIGINAL POWER SUPPLY CABLING - Electrical layout
Take care not to invert polarities when connecting the unit. If this happens, the plate does not come on
and the unit does not work.
Centrifugal
blower
2,6 Amp.
Az
Blue
N
Black
R
Red
V
Green
B
White
A
Yellow
Na Orange
M
Brown
Compressor
electronic
module
2 Compressor
IMPORTANT WARNING!
Electronic
module
24
Air conditioning for vehicles
Return
air sensor
NTC 15KΩ a 25º
Comsuption 30 mAmp.
Condenser
fan
2,9 Amp.
PWM.
Compressor
electronic
module
1 Compressor
Taking
positive
front