Using Coils; Troubleshooting - BGS technic 2169 Manual De Instrucciones

Calentador de inducción manual
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

USING THE COILS
Heating Coils
You-Form Coil (1 pc.)
Preformed Coil (5 pc.)
USING THE PERMORMED COIL
USES: The Preformed Coil is used to heat nuts, fasteners, caulking removal, door hinges, exhaust
manifold bolts, Sensors (O2) etc.
The working life of the Preformed Coil can be maximised by only heating objects enough to break the
rust bond. Leaving an air gap between the coil and the work piece is recommended as the insulation
of the coil will eventually burn through if held directly to hot material.
1. Carefully follow the "Preparation for Use" instructions.
2. Choose the appropriately sized coil to give the closest fit to the work piece (Nut/bolt etc) ensuring
an air gap of 5mm.
3. Insert both ends of the coil into the coil location socket and tighten the thumb screws securely.
4. Place coil centrally over the work piece.
5. Activate the power switch to run the INDUCTION HEATER until enough heat has been applied to
the work piece to break the rust/corrosion bond.
Tip: There is usually no reason to heat a nut to a red-hot condition in order to free it from the
corrosion holding it to the bolt.
6. Release the power switch to turn off the power.
USING THE YOU-FORM COIL
USES: The You-Form Coil can be shaped to perform any of the preformed coils jobs and can be
shaped to fit non standard fixings etc.
1. Carefully follow the "Preparation for Use" instructions.
2. Configure the coil to the size of the work piece by wrapping it around a socket or similar.
Tip: 3-4 coil winds is the optimum number.
3. Insert both ends of the YOU-FORM coil into the coil location sockets and tighten the thumb
screws securely.
4. Place coil centrally over the work piece.
5. Activate the power switch to run the INDUCTION HEATER until enough heat has been applied to
break the rust/ corrosion bond.
TIP: There is usually no reason to heat the work piece to a red-hot condition in order to break a
rust/corrosion bond.
6. Release the power switch to turn off the power.
TROUBLE SHOOTING
1. The INDUCTION HEATER inverter is designed to stop running if the internal components become
overheated, however, the attachments DO NOT have an overheat shutoff. We recommend a one
MINUTE duty cycle with the INDUCTION HEATER. (1 minute on – 1 minute off) If the unit stops
suddenly: check to ensure unit is still plugged into a functioning AC power outlet. Also be sure if
using an extension cord that there are no cuts in the cord. Allow the unit to cool off for at least 30
minutes and then retry.
2. If there is a lack of power output, this may be from using an improper extension lead or a
damaged attachment. The proper gauge and length of extension lead is 10 metres - 1.5mm² or 20
metres - 2.5mm². Do not use more than one extension cord at once.
BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
5
Tel.: 02196 720480
Fax.: 02196 7204820
mail@bgs-technic.de
www.bgstechnic.com
© BGS technic KG, Copying and further use not allowed