- The power indicator will show 1.
- The normal skin indicator
- The cation conduction (positive charge) indicator
will light up.
- On the
will light up.
● Set the timer using the
choose the operating time of the machine, in a
range of between 1 and 30 minutes.
● Set the power using the
choose the power of the machine, in a range of
between 1 and 9.
● Skin type selection: use the
the type of skin to be treated.
- When the indicator
skin type is normal.
- When the
skin type is sensitive.
- When the
skin type is very sensitive.
● Ion conduction selection: press
the polarisation of the probe with a red cable.
The probe with a black cable will always have the
polarity inverse to the one selected for the red
cable.
- One feature of this device is that the patient
should not hold any electrodes to close the
circuit, as one of the probes acts as positive and
the other probe acts as negative, thus closing the
circuit.
- When the
cation conduction (positive charge).
- When the
anion conduction (negative charge).
● Use the
- When running, the
- When paused or on standby, the
light up.
OPERATION
This device can be used with the roller probe
handpieces for large or regular areas of the skin, or
with the double stick probes for small or irregular
areas of the skin.
● Connect the device and leave it in standby mode
with the
indicator lit.
● Apply conductive gel or cream after cleaning the
skin to be treated.
● Select the type of skin to be treated, the operating
time and set the power to minimum.
● In order to correctly select the polarisation of
the ion conduction with the
value of the previously applied product should
be considered, selecting one or the other polarity
depending on whether it is an alkaline or an acidic
EN
4
will light up.
button, the pause indicator
or
buttons to
or
buttons to
button to select
lights up, the selected
indicator lights up, the selected
indicator lights up, the selected
to select
indicator lights up, it indicates
indicator lights up, it indicates
button to start or stop the device.
indicator will light up.
indicator will
button, the pH
product.
● Press
and the run indicator
up.
● Take the two probes (or the roller or double stick
ones) without letting them touch.
● Start to move them slowly and gradually set the
power until you reach the level necessary for the
treatment, always maintaining a slight stinging
sensation.
When applying this treatment on the face, it is
advisable to alternate the two probes (positive and
negative) on both sides of the face in order to make
equal effects on both sides of the face
Bear in mind:
● When the polarity is set for positive electrodes,
there will be a stinging sensation given off by the
roller probe that is stronger than the one given off
by the negative electrode. Select it according to
your needs.
● The selection of ion conduction to be used should
coincide with the pH of the product applied.
- When the probe with a red cable acts as a
positive charge, the conductive solution should
be acidic (+).
- When the probe with a red cable acts as a
negative charge, the conductive solution should
be alkaline (-).
- If the pH is not indicated in the solution to be
used, use a pH indicator strip to determine it.
● If the run indicator
is flashing, the circuit is not
closed and there is no ion conduction.
CLEANING AND MAINTENANCE
● Before cleaning the device, unplug it from the
mains.
● Clean the device with a soft, dry cloth. Do not use
liquids to clean it.
● After each use, the various components and
accessories must be sterilised and left to dry.
● For maintenance or repairs of any part of the
product, please contact your distributor or
specialised technician.
RECYCLING
If you need to dispose of the product or any of its
parts or accessories, please check and respect the
laws and regulations applicable to waste management
and environmental protection.