Power supply
If an extension cable is used, a 3 × 4 mm
the application site (e.g. outdoors) and labelled accordingly.
Undervoltage
Undervoltage
Undervoltage has a negative effect on the welding speed and quality !
2
mains cable must be used. The extension cable must be approved for
Heating power at +/- 10 % the
Rated voltage
Overvoltage
Voltage (V)
Rated voltage
Overvoltage
Voltage (V)
rated voltage
Voltage (V)
205
210
215
220
225
230
235
240
245
250
255
Voltage (V)
360
370
380
390
400
410
420
430
440
Heating power (W)
5164
5419
5680
5947
6221
6500
7686
7078
7376
7680
7990
Heating power (W)
5266
5563
5868
6180
6500
6831
7168
7513
7867