Do not work on pump until power is unplugged.
Do not cut off ground pin or use an adapter
fitting.
Do not use an extension cord.
The pump power cord should be connected to a
separately fused, grounded line with a minimum
capacity of 15 amps. It can be connected to non-
fuse breaker at the recommended amperes.
1. Before installing or servicing this pump, be
certain pump source is disconnected.
2. Installation and electrical wiring must adhere
to state and local codes and must be
completed before priming pump. Check
appropriate community agencies, or contact
local electrical and pump professionals.
3. Call an electrician when in doubt. Pump
should be connected to a separate 15
amp circuit breaker or 15 amp fuse block.
Note that plugging into existing outlets may
cause low voltage at motor. This could cause
blown fuses, tripping of motor overload or
burned out motor.
4. A permanent ground connection from pump
to the grounding bar at the service panel is
mandatory. These sump pumps come with a
grounding conductor and a grounding-type
attachment plug. Do not connect pump to
a power supply until permanently grounded.
For maximum safety, connect pump to a circuit
equipped with a fault interrupter device when
positioning the pump's grounding wire.
5. Voltage of power supply must match the
voltage of the pump.
6. Before installing pump, clear sump basin of
any water, debris or sediment.
in accordance with local
plumbing codes. These Sump pumps are not
designed for and CANNOT be installed in locations
classified as hazardous.
7. The following may cause severe damage to
pump and will void the warranty.
(a) Using an extension cord.
(b) Cutting off the ground pin or using an
adapter fitting.
(c) Working on pump or switch while
plugged in.
Submersible Utility Pumps
Model: UT56 & UT80 Series
Installation
Sump basin must be vented
(d) Removing motor housing, unscrewing
impeller, or otherwise removing impeller seal.
(e) Running the pump continuously.
(f) Pumping chemicals or corrosive liquids.
(g) Pumping gasoline or other flammable liquids
9. Plastic PVC pipe can be installed in the
outlet piping. Drain hose, galvanized steel
or copper pipe may be used if desired.
All piping must be clean and free of all
foreign matter to prevent clogging.
10.Pump will be inadequate if suspension
liquids contain solid particles larger than 1/8"
ELECTRICAL WIRE CONNECTION
the nameplate corresponds to those available on the
mains. The installer must make sure that the
electric system is grounded in accordance with code.
• For outdoor use it is necessary to use cable
with a length of at least 8'. The plug and
connection should be protected from water
splashes. Before using the pump, always in
spect it visually (especially power cable and
plug)
• Do not use pump if it is damaged
• If the pump is damaged, have it inspected by
an authorized service center.
• Make sure that electric connections are pro
tected from flooding. Protect the plug and the
power cable from heat or shape edges.
Grounding: The plug of the power cable has a double
grounding contact, so that grounding can be performed
by simply inserting the plug.

OVERLOAD PROTECTION

This pump series has a built in thermal protection
switch. The pump stops if an overload condition occurs.
The motor restarts automatically after it has cooled
down.
5
Verify that the voltage and
frequency of the pump shown on
The power cable must be re
placed by qualified personnel only.