If this advice is not followed, water may leak into the wall.
N
DELABIE cannot be held responsible for any ingress.
FOR FURTHER INFORMATION PLEASE CALL DELABIE TECHNICAL
SUPPORT UK: 01491 821821. ALL OTHER MARKETS: +33 (0)3 22
ds
60 22 74.
REMEMBER
s
Our valves must be installed by professional installers in
•
accordance with current regulations and recommendations in your
country, and the specifications of the fluid engineer.
Sizing the pipes correctly will avoid problems of flow rate, pressure
•
loss and water hammer (see calculation table in our brochure and
online at www.delabie.com).
•
Protect the installation with filters, water hammer absorbers
and pressure reducers to reduce the frequency of maintenance
(recommended pressure from 1 to 5 bar maximum).
Install stopcocks close to the valve to facilitate maintenance.
•
•
The pipework, filters, non-return valves, stopcocks, bib taps, cartridge
and all sanitary fittings should be checked at least once a year, and
more frequently if necessary.
CHEMICAL AND THERMAL SHOCKS
This product has been designed to withstand both thermal and chemical
shocks in line with current regulations.
MAINTENANCE
Mixer: check once a year, and as often as necessary, the temperature
selector and the mixer's two internal seats on which the mixing key turns.
F
In the event of malfunction, clean or replace worn or damaged parts.
We recommend an annual check of the following items:
NG
Non-return valves and filters: de-scale and replace worn or
•
L
damaged parts.
Inter-changeable cartridge: de-scale internal parts and replace
•
L
worn or damaged parts.
VE
34