ONDULADOR CC/CA 1300VA para aplicación Industrial y Ferroviaria
1300VA DC/AC INVERTER for Industrial and Railway application
RS232 communications
Configuration: 9600 bauds, parity none, 8 bits, 1bit stop
Protocol in ASCII code
Header
Function
Parameter
L
Other
P
R
character
3
4
G
6
8
www.premium.es
Returns
Description
PTU■■■.■
U
Output voltage in Volts RMS
PTT■■■.■
T
Internal temperature in ºC
PTF■■■.■
F
Output frequency in Hz
Inverter status
999.9 → Enabled
PTS■■■.■
000.0 → Disabled
S
111.1 → Inverter blocked by overload
or shortcircuit
PTM■■■■
M
Model number
PTR■■■■
R
Firmware version
PTE
Command not supported
Changes the inverter status
■■■.■
999.9 → Enabled
OK / ERR
000.0 → Disabled
Set the output voltage in Volts RMS
■■■.■
OK / ERR
Changes the output frequency
(Not saved for the next start-up)
■■■.■
OK / ERR
005.0 → 5Hz
063.0 → 63Hz
■■■.■
111.1 → Reset the inverter
OK / ERR
Note:OK(Data accepted) / ERR(Data not valid for the current parameter)
Nota: OK (Dato aceptado) /ERR (Dato no válido para el parámetro actual)
Configuración: 9600 baudios, sin paridad, 8 bits, 1bit stop
≤ ■■■.■ ≤ 250 V
50 V
RMS
RMS
4/7
Comunicaciones RS232
Protocolo en código ASCII
Descripción
Tensión de entrada en Voltios
Temperatura interna en ºC
Frecuencia salida en Hz
Estado del inversor
999.9 → Activado
000.0 → Desactivado
111.1 → Inversor bloqueado por sobrecarga o
cortocircuito
Número de modelo
Versión de firmware
Comando no suportado
Cambiael estado de inversor
999.9 → Activado
000.0 → Desactivado
Establece la tensión de salida en Voltios RMS
≤ ■■■.■ ≤ 250 V
50 V
RMS
Cambia la frecuencia de salida
(No se guarda para el siguiente arranque)
005.0 → 5Hz
063.0 → 63Hz
111.1 → Reset delinversor
04-01-2018
9502145-3
ODX-1300
RMS
CA-563-3