ONDULADOR CC/CA 1300VA para aplicación Industrial y Ferroviaria
1300VA DC/AC INVERTER for Industrial and Railway application
Altitud de trabajo
4.1.1
Working altitude
Temperatura ambiente
4.1.2
Ambient temperature
Choques y vibraciones
4.1.3
Shocks and vibrations
Humedad relativa
4.1.4
Relative humidity
Variaciones de la tensión de alimentación
5.1.1.1
Power supply voltage variations
Interrupciones de la tensión de alimentación
5.1.1.2
Power supply interruptions
Factor de ondulación a la entrada
5.1.1.4
Input ripple factor
Conmutación de la alimentación
5.1.3
Power supply switching
Sobretensiones de alimentación
5.2
Power supply over-voltages
CEM Compatibilidad electromagnética
EMC Electromagnetic Compatibility
5.5
EN50121-3-2:2016
Protección inversión de polaridad de entrada
7.2.6
Input reverse polarity protection
Recubrimiento de protección del PCB
9.7
PCB protection
Lista de ensayos
12.2
Tests list
www.premium.es
ANEXO / ANEXE
Valores aplicables para los apartados de la norma EN50155: 2007
Applicable values for the different sections of the norm EN50155: 2007
According EN50125-1:2003 Class A2 (up to 1000m)
Class T1 column 2 full load
Class T2 column 2 50% load
According EN61373:2010 Category 1 class B
Up to 95%
From 0.70 to 1.25 Un continuous
From 0.60 to 1.40 Un 0.1s
From 1.25 to 1.40 Un 1s without damage
Class S1 (without interruptions)
Up to 15% peak to peak of Vin nom
Class C1 (0.6 Un during 100ms without interruptions)
1.40 Un 1s (impedance 1 ohm)
Test
Radiated
emissions
Conducted
emissions
Test
Electrostatic
discharge
Radiated
high-frequency
Fast transients
Surge
Conducted RF
P = Performance criteria, L= Line, P= PE (Protective Earth)
By external fuse
PCB conformal coated
1 Visual Inspection
2 Performance
3 Cooling
4 Dry heat
6 Supply
7 Surge, ESD and burst susceptibility
8 RF Interferences
9 Insulation
11 Shocks and vibrations
13 Equipment stress screening:24h at 40°C and load 100%
14 Low temperature storage
Norm
Port
IEC55016
Enclosure
IEC55016
Input
Norm
Port
IEC61000-4-2
Enclosure
IEC61000-4-3
X/Y/Z Axis
Input
IEC61000-4-4
Output
Signal
Input L to L
IEC61000-4-5
Input L to P
Input
IEC61000-4-6
Output
Signal
overvoltages
7/7
Frequency
30MHz...230MHz
40dB(µV/m) Qpk at 10m
230MHz...1GHz
47dB(µV/m) Qpk at 10m
1...3GHz
Do not apply
3...6GHz
Internal freq. < 108MHz
150kHz...500kHz
99dB(µV) Qpk
500kHz...30MHz
93dB(µV) Qpk
Severity
Conditions
±8kV
Air (isolated parts)
±6kV
Contact (conductive parts)
0.08...1GHz M. 80% 1kHz
20V/m
1...2GHz M. 80% 1kHz
10V/m
2...2.7GHz M. 80% 1kHz
5V/m
5.1...6Ghz M. 80% 1kHz
3V/m
±2kV
Tr/Th: 5/50 ns
±1kV
Tr/Th: 1.2/50µs
±2kV
10V
0.15...80MHz M. 80% 1kHz
Routine
Routine
Type
Type
Type
Type
Type
Routine
Type
Routine
Type
04-01-2018
9502145-3
ODX-1300
Limits
P
B
A
A
B
A
CA-563-3