Gas Connection - Orima OR 645 XF Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Gas Connection

WARNING: Before starting any work related with gas installation, turn off
gas supply. Risk of explosion.
Please operate your oven in dry atmosphere.
1. Fit the clamp to the hose. Push one of the hose until it goes to the
end of the pipe.
2. For the sealing control; ensure that the buttons in the control panel are
closed, but the gas cylinder is open. Apply some soap bubbles to the
connection. If there is gas leakage, there will be foaming in the soaped area.
3. The oven should be using a well ventilation place and should be
install on flat ground.
4. Re-inspect the gas connection.
5. When placing your oven to its location, ensure that it is at the counter
level. Bring it to the counter level by adjusting the feet if necessary.
6. Do not make gas hose and electrical cable of your oven go through theheated
areas, especially through the rear side of the oven. Do not move gas connected
oven. Since the forcing shall loosen the hose, gas leakage may occur.
7. Please use flexible hose for gas connection.
For LPG connection;
Main Gas Pipe
Gasket
Hose Inlet Connector
Metal Clamp
Lpg Connection Hose
NOTE: The regulator to be affixed on LPG cylinder should have 300
mmSS feature.
For LPG (cylinder) connection, affix metal
clamp on the hose coming from LPG
cylinder. Affix an edge of the hose on hose
inlet connector behind the appliance by
pushing to end through heating the hose
in boiled water. Afterward, bring the clamp
towards end section of the hose and tighten
it with screwdriver. The gasket and hose inlet
connector required for connection is as the
picture shown below.
59

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido