1.
Inspect your pump. Occasionally, products are damaged during shipment. If the unit or any of the parts are damaged, contact your dealer before using.
2.
Read all the installation instructions regarding installing and start up before performing any of the work described within. Retain for future reference.
SEE BELOW FOR LIST OF WARNINGS
1.
For your protection always disconnect the power supply from its power source
before handling the components of your primary pump.
2.
Sump water is non-potable. To reduce the risk of contamination of the
potable water supply, the Home Guard
listed backflow device suitable for the installation, in accordance with
the local plumbing code, such as a reduced pressure principle backflow
preventer (RP). Alternately, consult the local plumbing and health codes
or the authority having jurisdiction for guidance on cross-connection and
backflow protection requirements.
CAUTION
Turbulence caused by high velocity incoming water can
negatively affect the on/off action of the float mechanism. If this condition
exists, the incoming water must be baffled to avoid excessive turbulence.
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
TEL: (502) 778-2731 • 1 (800) 928-PUMP • FAX: (502) 774-3624
MODEL 503
WATER POWERED EMERGENCY BACKUP
SUMP PUMP SYSTEM
PVC CONSTRUCTION
PREINSTALLATION CHECKLIST
Max must be installed with a
®
REFER TO WARRANTY ON PAGE 2.
© Copyright 2020 Zoeller
®
SEE BELOW FOR LIST OF CAUTIONS
1.
This pump is designed for handling clear water. Do not use in septic tanks
to pump effluent or sewage pits to pump sewage.
2.
Repair and service of your backup system should be performed by an
authorized service station.
3.
The installation of this backup pump requires the use of a variable level
float switch for operation. It is the responsibility of the installing party, to
ensure that the float switch will not hang up on the pump apparatus or
pit peculiarities and is secured so the pump will turn "on" and "off". It is
recommended that the pit be 18" in diameter or larger to accommodate both
a primary and a backup pump.
4.
Check the installation of the primary and backup pump floats to ensure
that both move freely and are not being encroached upon where the float
cannot move. Adequate space between the floats must be maintained.
5.
The pump should be manually activated once a month by lifting the float
rod. Let the pump run for at least 15 seconds to prevent the pump from
building up calcium deposits and debris, which could harm the pump.