Performance Characteristics; Troubleshooting Guide - Zoeller Home Guard Max 503 Manual Del Usuario

Sistema de bomba de sumidero auxiliar de emergencia accionada por agua construido en pvc lista de verificación para la preinstalación
Ocultar thumbs Ver también para Home Guard Max 503:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PUMP PERFORMANCE
CURVE
MODEL 503
14
45
40
12
35
10
30
8
25
20
6
60 PSI
15
40 PSI
4
10
2
5
0
5
10
15
GALLONS
LITERS 0
20
40
60
FLOW PER MINUTE
CONDITION
PUMP WILL NOT START OR
A
RUN
B
PUMP STARTS TOO SOON
C
PUMP WILL NOT SHUT OFF
PUMP OPERATES BUT
D
DELIVERS LITTLE OR NO
WATER

PERFORMANCE CHARACTERISTICS

MODEL
Feet
5
10
15
20
25
30
35
80 PSI
40
Shut-off Head:
Pump capacity varies due to: Inlet Water Pressure, Working Water Pressure, Discharge Elevation, Number
of Pipe Fittings, Inlet and Outlet Pipe Size, Fluid Viscosity, Degree of Water Clarity, Water Temperature.
The flow rates in the chart are approximate values.
NOTE: Some districts may require a reduced pressure principle backflow preventer per ASSE Standards
1013. Check Local Codes.
20
25
suitable for the installation, in accordance with the local plumbing code, such as a reduced pressure
principle backflow preventer (RP). Alternately, consult the local plumbing and health codes or the
80
authority having jurisdiction for guidance on cross-connection and backflow protection requirements.

Troubleshooting Guide

POSSIBLE CAUSE
Inadequate incoming water pressure.
Excessive incoming water pressure.
Debris around Intake.
Float hung up on pit or primary pump
Float "ON" point is adjusted too low.
Float is obstructed.
Float "OFF" point is adjusted too low.
Foot valve above water level.
Internal valve diaphragm vent hole is
plugged with debris.
Water level in sump pit was below
foot valve when pump was activated.
Debris around Intake.
Inadequate incoming water pressure.
Blockage in discharge pipe.
Foot valve above water level.
Vertical lift too high.
© Copyright 2020 Zoeller
TOTAL DYNAMIC HEAD/FLOW
TOTAL DYNAMIC HEAD/FLOW
PER MINUTE
PER MINUTE
DEWATERING ONLY
DEWATERING ONLY
40 PSI
Meters
Gal.
Liters
1.5
12.7
48.1
3.0
12.7
48.1
4.6
7.4
28.0
6.1
2.0
7.6
7.6
-
-
9.1
-
-
10.7
-
-
12.2
-
-
22.0 ft. (6.7 m)
34.0 ft. (10.4 m)
Sump water is non-potable. To reduce the risk of contamination of the potable
water supply, the Home Guard
Max must be installed with a listed backflow device
®
REMEDY
Check incoming water line for closed valve, low water
pressure or clogged filter/strainer.
Install regulator and reduce pressure below 100 PSI with
valve closed.
Clear debris from pit and foot valve strainer.
Move pumps so that the floats move freely and do not
contact pit, piping or each other.
Refer to STEP 2.
Inspect float operation and correct problem.
Refer to STEP 2.
Adjust Float - Refer to STEP 2.
Turn off water supply to pump and back on repeatedly
to dislodge debris. If this process does not remedy the
problem, service pump to clear debris or replace valve
assembly.
Turn off water supply to pump. Fill pit with water until the
foot valve is submerged. Turn on water supply and activate
float by hand. Allow pump to run for 3-5 seconds and
release float before the foot valve is above the water level.
Pump should shut off normally.
Clear debris from pit and foot valve strainer.
Check incoming water line for closed valve or low water
pressure.
Remove pipe and flush out debris.
Adjust Float - Refer to STEP 2.
Change discharge piping or contact technical service.
Co. All rights reserved.
®
6
503
60 PSI
80 PSI
Gal.
Gal.
Liters
Liters
19.0
72.0
20.0
75.7
19.0
72.0
20.0
75.7
15.0
56.8
20.0
75.7
11.1
42.0
20.0
75.7
7.1
26.9
15.3
57.9
3.2
12.1
10.9
41.3
-
-
6.4
24.2
-
-
1.8
6.8
42.0 ft. (12.8 m)
018586