7.5 Terminal assignment table for Sorting Inline
Digital (XG1)
Function
SysLink
I0
13
I1
14
I2
15
I3
16
I4
17
I5
18
I6
19
I7
20
Q0
1
Q1
2
Q2
3
Q3
4
Q4
5
Q5
6
Q6
7
Q7
8
24 V A
9+10
24 V B
21+22
GND A
11
GND A
12
GND B
23+24
7.6 Networking the system
In the case of the MPS system 404-1 with Siemens controllers, the controllers, the PROFINET bus node, and
the RFID gateways are connected to each other via three 8-port switches. These switches are found at the
rear in the respective stations in the carriage.
30
Color
Gray-pink
Red-blue
White-green
Brown-green
White-yellow
Brown-yellow
White-gray
Gray-brown
White
Brown
Green
Yellow
Gray
Pink
Blue
Red
Black
White-pink
Brown-pink
Purple
White-blue
Cable jumpers are connected from emergency stop to bit 1.5 for all PLC EduTrainer
universal standard MPS versions.
Designation
Workpiece at start of conveyor
Deflector 1 advanced
Deflector 2 advanced
Slide is full/workpiece not at end of conveyor
Workpiece detected
Workpiece not black
Workpiece metallic
Conveyor forward
Conveyor belt reverse
Advance deflector 1
Advance deflector 2
24 V supply for outputs
24 V supply for inputs
0 V power supply for outputs
0 V power supply for outputs
0 V power supply for inputs
© Festo Didactic 8150266