5.5. Precautionary measures to be taken by the operator
IBS-Parts Cleaning Devices conform to type class A 1 (EN 12921-3; 3.15.1).
A danger area which is appropriate for the operating conditions (e.g. geometry and surface area of workpieces, intensity
of cleaning) must be defined. For normal cleaning processes, IBS recommends a danger area of 2 m around the device.
DANGER!
The danger area identified by means of a risk assessment:
∙
Must be designated a fire hazard area
EN
∙
Must remain free of obstructions in order to allow unimpeded access at all times
∙
Must be equipped with effective natural ventilation
∙
Smoking is not permitted in the danger area
∙
Naked flames or other sources of ignition are not permitted in the danger area
∙
Keep everything as clean as possible when working with cleaning agents, oils and lubricants
∙
Operating and maintenance personnel must receive proper training
∙
The operating instructions and the standard operating procedure must be attached to the device
6. OPERATING THE MACHINE
6.1. Controls
The device is equipped with a device main switch (rocker switch).
6.2. Assembly and adjustment
6.2.1. Assembling the Parts Cleaning Device
∙
Remove the packaging.
∙
Lift the support (2) and place it to one side. Fill the tub (5) with max. 35 litres of IBS-Special Cleaner.
∙
Plug the cleaning brush (4) into the cleaning agent supply line (3).
∙
Using the handle (1), position the device under the vehicle or suspension part to be cleaned in such a way that the cleaning liquid
can be reliably collected — adjust the device if necessary. Please ensure placement on an even surface.
∙
Lock the two front castors (6) of the device.
48
IBS-BA_Typ_A-DE_CZ_PL_ES_EN_04.2020
1
2
7
6
3
4
5