5.5. Precautionary measures to be taken by the operator

IBS-Parts Cleaning Devices conform to type class A 1 (EN 12921-3; 3.15.1).
A danger area which is appropriate for the operating conditions (e.g. geometry and surface area of workpieces, intensity
of cleaning) must be defined. For normal cleaning processes, IBS recommends a danger area of 2 m around the device.
DANGER!
The danger area identified by means of a risk assessment:
Must be designated a fire hazard area
EN
Must remain free of obstructions in order to allow unimpeded access at all times
Must be equipped with effective natural ventilation
Smoking is not permitted in the danger area
Naked flames or other sources of ignition are not permitted in the danger area
Keep everything as clean as possible when working with cleaning agents, oils and lubricants
Operating and maintenance personnel must receive proper training
The operating instructions and the standard operating procedure must be attached to the device

6. OPERATING THE MACHINE

6.1. Controls

The device is equipped with a device main switch (rocker switch).

6.2. Assembly and adjustment

6.2.1. Assembling the Parts Cleaning Device

Remove the packaging.
Lift the support (2) and place it to one side. Fill the tub (5) with max. 35 litres of IBS-Special Cleaner.
Plug the cleaning brush (4) into the cleaning agent supply line (3).
Using the handle (1), position the device under the vehicle or suspension part to be cleaned in such a way that the cleaning liquid
can be reliably collected — adjust the device if necessary. Please ensure placement on an even surface.
Lock the two front castors (6) of the device.