VENTILATION FAN
WITH LED LIGHT
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the
address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to
a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit.
8. Not for use in kitchens.
9. This unit must be grounded.
10. This unit is U.L. listed. Type I.C. inherently protected.
!
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. This product is designed for installation in FLAT CEILINGS
ONLY. Do not mount this product in a wall.
3. The light fixture assembly must be mounted to the fan
housing assembly included with this product. Do not mount
the light fixture assembly to a wiring outlet box.
4. To avoid motor bearing damage and noisy and/or
unbalanced impellers, keep drywall spray, construction
dust, etc. off power unit.
5. Please read specification label on product for further
information and requirements.
Installer: Leave this manual with the
homeowner.
Homeowner: Use and Care
information on page 4.
TYPICAL INSTALLATIONS
CEILING
JOIST
HOUSING
HOUSING
CEILING
MATERIAL
HOUSING MOUNTED
DIRECTLY TO JOIST
2x6 (or larger)
Discharge parallel to joists.
"
"
I
JOIST CEILING
HOUSING MOUNTED TO "I" JOIST
Requires additional framing
Discharge parallel to joists.
*
Additional framing must be a 2x6 (minimum height).
PLAN THE INSTALLATION
INSULATION
(Place around and
over fan housing.)
FAN
HOUSING
POWER
CABLE*
Seal gaps
around
housing.
4-IN. ROUND
DUCT*
Seal duct
joints with
*Purchase
tape.
separately.
2 x 4
CEILING
JOIST or
TRUSS
CEILING
GRILLE
MATERIAL
HOUSING MOUNTED
TO 2x4 TRUSS
Discharge parallel to joists.
ADDITIONAL
FRAMING
HOUSING
HOUSING
"
I
JOIST
GRILLE
MATERIAL
for mounting.
OR
4-IN. ROUND
ELBOWS*
MODEL 791LED
Page 1
2 x 4
CEILING
JOIST or
TRUSS
HOUSING
HOUSING
GRILLE
*
"
ROOF CAP*
(with built-in
damper)
Keep duct
runs short.
WALL CAP*
(with built-in
damper)

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Broan 791LED

  • Página 1 MODEL 791LED Page 1 VENTILATION FAN WITH LED LIGHT READ AND SAVE THESE INSTRUCTIONS TYPICAL INSTALLATIONS WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 2 x 4 2 x 4 1. Use this unit only in the manner intended by the manufacturer.
  • Página 2 MODEL 791LED Page 2 INSTALL THE HOUSING NOT FOR USE IN A COOKING AREA Do not install above or inside this area New Construction 1. Choose the location for your fan/light in the ceiling. For best possible performance, use the shortest possible duct run and a minimum number of elbows.
  • Página 3: Connect The Wiring

    MODEL 791LED Page 3 SEAL BETWEEN CEILING FINISH THE INSTALLATION 4. Place housing in MATERIAL & HOUSING opening so that its bottom edge is flush with finished ceiling. Screw housing to joist through holes in 1. Re-install blower housing as shown.
  • Página 4: Cleaning And Maintenance

    KEY NO. PART NO. DESCRIPTION Limited Warranty Warranty Period and Exclusions: Broan-NuTone LLC (the “Company”) warrants to the original consumer 97019447 Grille Assembly purchaser of its product (“you”) that the product (the “Product”) will be free from material defects in the Product or its workmanship for a period of one (1) year from the date of original purchase.
  • Página 5 MODELO 791LED Página 5 VENTILADOR CON LUZ LED LEA Y CONSERVE ESTAS INSTRUCCIONES ADVERTENCIA INSTALACIONES TÍPICAS PARA REDUCIR EL RIESGO DE INCENDIOS, DESCARGAS ELÉCTRICAS O LESIONES PERSONALES, SIGA LAS SIGUIENTES PRECAUCIONES: VIGUETA o VIGA VIGUETA o VIGA VIGUETA DE DE 2 x 4 DE DE 2 x 4 DE 1.
  • Página 6: Instalación De La Cubierta

    MODELO 791LED Página 6 INSTALACIÓN DE LA CUBIERTA NO USAR EL PRODUCTO EN UN ÁREA DE COCINA No instale el equipo sobre o dentro de esta área Nueva construcción 1. Seleccione la ubicación del ventilador con lámpara en el cielo raso.
  • Página 7: Instalación Del Sistema De Conductos

    MODELO 791LED Página 7 APLIQUE SELLADOR ENTRE EL MATERIAL FINALIZACIÓN DE LA INSTALACIÓN 4. Coloque la cubierta en la DEL CIELO RASO Y LA CUBIERTA abertura de manera que su borde inferior quede al ras del cielo raso terminado. Atornille la cubierta en la vigueta a través de los orificios de la...
  • Página 8: Limpieza Y Mantenimiento

    N.º DE CLAVE N.º DE PIEZA DESCRIPCIÓN Garantía limitada Periodo y exclusiones de la garantía: Broan-NuTone LLC (la “Compañía”) garantiza al consumidor comprador original de su 97019447 Conjunto de la rejilla producto (“usted”) que el producto (el “Producto”) estará libre de defectos en materiales en el Producto o en la mano de obra, (incluye claves N.

Tabla de contenido