Riello 464T58 Manual Del Usuario página 8

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

NOTE:
The burner is provided with a socket for the direct electrical connection to the boiler's
plug (see diagram at page 5). Should the boiler be without plug, it is then necessary:
– remove the socket and respective cable mounted on the burner;
– carry out the electrical connection direct to the wiring terminal block of the burner as shown on
the diagram below.
ELECTRICAL WIRING
WARNING
DO NOT EXCHANGE THE
NEUTRAL WITH THE PHASE
~
220V
N
N
1
2
3
Valve
Black
D5228
2399
60Hz
L
Main switch
T6A
L
4
5
6
7
M
~
Black
Capacitor
Motor
NOTES:
– Wires of min. 1 mm
(Unless requested otherwise by local
standards and legislation).
– The electrical wiring carried out by the
installer must be in compliance with the
rules in force in the Country.
T
T
Remote lock-out signal
(220V - 0.5A max.), if required
TERMINAL BLOCK OF
8
9
CONTROL-BOX 530SE *
6
GB
2
section.
Limit thermostat
Safety thermostat
CARRIED-OUT
IN THE FACTORY

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

G103746464

Tabla de contenido