2.3
Data communication / Bus
The device is equipped with a VBus
Carry out the connection at the two terminals marked VBus (any polarity).
2.4
Example
14
for data communication with the controller.
®
copy controller relay
0 (8) = PWM (+ cloned)
9 (7) = 0-10V (+ cloned)
3
Operation
3.1
Selector switch
The selector switch is used for adjusting the operating mode of the EM-HP.
Switch position
Operating mode
0
The speed control signals of the controller relays 1 ... 4 are
copied and emitted as speed control signals (PWM) over the
0
HE outputs 1 ... 4 of the EM-HP.
Additionally, the corresponding relays 1 ... 4 of the EM-HP
are switched on.
9
The speed control signals of the controller relays 1 ... 4 are
copied and emitted as speed control signals (0-10 V) over the
0
HE outputs 1 ... 4 of the EM-HP.
Additionally, the corresponding relays 1 ... 4 of the EM-HP
are switched on.
8 ... 1
No function. The HE outputs 1 ... 4 of the EM-HP emit a 0 %
speed control signal. Relays 1 ... 4 of the EM-HP are switched
0
off.
3.2
Curve
Input
inverted (Heating)
PWM
10 V
20 mA
0%
not inverted
(Solar)
Output
100 %
PWM
10 V
20 mA
100%