Water Ace R520C-T7 Manual De Instalación página 5

Sistema de tanque de chorro
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Remove pipe clamp and slide
STEP
Well Seal #RWS4-12 over
4
PVC pipe and onto well
casing. Position assembly
so twelve inches of PVC pipe protrude
from well seal. Alternately turn bolts on
well seal counterclockwise until rubber
gaskets are tight against well casing
and PVC pipe.
Cement 1-1/4" PVC elbow
STEP
onto PVC pipe protruding
5
from well seal. If desired,
some length may be cut off
of PVC pipe before cementing elbow.
Smooth inside of any cut PVC pipe
with file or knife.
Open ejector
STEP
pack included
6
with your jet
system. The
ejector has two holes in
its top. Thread the shallow
well venturi tube (part #25882A437 stamped on the side)
into larger hole until snug. Put gasket over venturi tube so
openings in gasket line up with openings in ejector.
Secure ejector and gasket to
STEP
front of tank-mounted pump
7
with bolts provided. Thread
a 1-1/14" male PVC adapter
into front of ejector.
Cement as much PVC pipe and couplings as needed
STEP
to connect PVC elbow to male PVC adapter in
8
front of ejector. The diaphragm pressure tank is
preset to 30 PSI. Reset pressure to 28 PSI using
a tire gauge. This is vital to proper operation of
the system.
TO PRIME: Remove
STEP
pressure regulator from
9
top of pump. Put a
garden hose into top of
pump and fill pipes and pump until
water overflows from top of pump.
This may take several minutes.
(Make sure pressure regulator
screw is adjusted to flow.)
APPROX.
12" OF
PVC PIPE
PROTRUDING
FROM WELL
SEAL
WELL
SEAL
#RWS4-12
1-1/4"
PVC
ELBOW
TOP OF
PVC PIPE
PROTRUDING
FROM WELL
SEAL
VENTURI
BOLTS
GASKET
TUBE
EJECTOR
EJECTOR
MALE PVC
ADAPTER
PRESSURE
PRESSURE
GAUGE
REGULATOR
ADJUSTMENT
Thread pressure
STEP
regulator back
10
into discharge
of pump. Make
sure all connections are
tightly sealed. Place a large
basin beneath diaphragm
tank outlet. Start motor. If
pump is off-set from well
4 feet or more, it may take
a few minutes for pump to
prime. Failure to prime in 5
minutes: Stop motor, remove
pressure regulator from pump, add more water, try again.
Allow pump to run long enough to clear the well of sand
or dirt and to ensure well will not run dry. Stop motor.
Connect the 1" tank outlet to the service
STEP
line. Total installation should look like the
11
drawing below.
COMPLETE
SHALLOW WELL
INSTALLATION
5
23833A203

Publicidad

Tabla de contenido
loading

Tabla de contenido