DISCAFLEX - - USER'S GUIDE
If Discaflex runs on a level switch in the last pen : make sure that there are always enough animals in that pen.
HINT : install the level switch as low as possible.
If Discaflex starts from 2 feed bins : use one bin or the other. Never use both bins at the same time.
You can use Discaflex for most of the current commercial feeds.
Other feed mixture can make the operation of Discaflex more difficult. Feeds mixed with CCM can disturb the operation of
the system. For other applications: contact Roxell.
The filling degree can change according to the kind of feed. Adjust the capacity so that the disks become visible.
The adjustment of the intake boot is different for mash and pellets.
NEVER allow that too much feed enters the circuit, or that the circuit is filled twice.
Minimum
Figure 1.
Maximum
Figure 2.
Figure 3.
4
OPERATOR'S GUIDE
DETERMINE THE IDEAL FILLING DEGREE
Disks
Position maximum capacity.
Adjust the capacity so that the disks become visible.
Position minimum capacity.
ROXELL - - 048 - - 0511