INSTRUCTIONS INTENDED SOLELY FOR
QUALIFIED PROFESSIONALS
3.3 CONNECTING THE ALARM
SANICONDENS
Best Flat is fitted with a detection
®
system that can cut off the power supply to the connected
appliance if the water level rises too high. To connect the
detection system, connect the other set of cables, black
and grey (see "Alarm" label), to the appliance (refer to the
instructions of the appliance). See fig. 10.
NOTE: It is possible to connect the detection system
to an external alarm (audible or visual, from1.5V to
230V) by changing the connection of the detection
system. SANICONDENS
by a dry contact supplied NC (normally closed, fig. 10).
To connect the external alarm, this contact must be
changed to NO (normally open, fig. 11.3). To do this,
open the cover (fig. 11.1), unplug the grey wire from its
location and plug it to the free contact above (fig. 11.2).
- ATTENTION : The maximum current admissible for
our detection system is 0.5A.
- To protect the electrical components in the
SANICONDENS
Best Flat, once the alarm has
®
been triggered, any water continuing to fill the tank
comes out through the overflow outlets of the tank
3.4 MAIN CONNECTION
The pump sould be connected to a fully grounded
electrical supply.
Connect the power cable L to the SANICONDENS
Best Flat (fig. 9) and then to the main power supply
GFI outlet. Comply with local installation requirements.
3.5 USE
Functional test
Before turning on the pump, make sure you
remove the protective lock pin from the rear of
the device (fig. 5).
- Pour water into the tank.
- Check that the pump starts and stops when the
water level drops.
- Check that there are no leaks in the connections.
Filling the neutralizer compartment
- Remove the cover from the neutralizer compartment
(fig. 7).
- Add the neutralizing granules into this section (fig.8).
- Reposition the cover and clip it in place.
SANICONDENS
Best Flat is ready to use.
®
Example of an installation of a
SANICONDENS
Best Flat : see pg. 1.
®
STANDARDS
4
SANICONDENS
Best Flat is eligible to bear the
®
CSA mark shown with adjacent indicators "C" and "US".
The "C" and "US" indicators adjacent to the CSA mark
signify that the product has been tested according to
the applicable CSA (CDN) and ANSI/UL standards for
use in Canada and the USA. This includes products
eligible bear the designation NTRL. NTRL (Nationally
Recognized Testing Laboratory) is a designation
awarded by the American Occupational Safety
and Health Administration (OSHA) to laboratories
authorized to award the certification according to
American standards.
Best Flat is controlled
®
5
INTERVENTIONS
Disconnect electrical power
before working on the unit !
5.1 MAINTENANCE (FIG. 12)
Check the quality of the neutralizing granules regularly.
If neeeded, use a pH test strip to determine this.
Neutralizing granules need to be replaced at least
once a year. This may vary depending on its usage.
When replacing the granules, make sure to clean the
compartment as well.
5.2 TROUBLESHOOTING
If a breakdown occurs, any service on the unit should
be carried out by a qualified technician. In particular
the replacement of the power cable.
Fault detected
The pump doesn't
start
.
®
The pump does
not lift
LIMITED WARRANTY
6
This SFA appliance bears a 3 year warranty starting from
the date of purchase, subject to proper installation and
use, in compliance set out in this notice.
Warranty issues will be handled by the Technical
Department and will be subject to correct installation
and usage. If a replacement is to be issued, this will be
only extended to the first 180 days starting from the date
of purchase and will need to be approved by one of our
company's representative. Warranty repairs will apply
after such date up to the warranty's date of conclusion.
Plumber's invoices for any type of repair, disconnection
and reconnection are not covered by the warranty
and are the end user's responsibility. In no event shall
the company be liable for any special, incidental or
consequential damage, loss or injury of whatsoever
nature or kind arising from or in connection with the
product or any component thereof.
8
INSTRUCTIONS INTENDED SOLELY FOR
QUALIFIED PROFESSIONALS
Probable causes
Action needed
The pump is not
Plug in the unit
connected to the
power supply
The lock pin has not
Remove the lock
been removed
pin
The unit is not leveled Check the unit
with a leveling
tool
Power outage
Check the main
power in the
house
Float blocked
Clean the tank
Condensate inlet pipe
Clean the inlet
blocked
pipe
Non-return valve
Clean the valve
blocked
Discharge pipe
Clean the
blocked
discharge pipe
US