STEP ONE: CLEAN UP INSTRUCTIONS
NOTE: Proper clean up is essential to keep your sprayer in optimum working condition.
Dried by-products act like glue and will cause moving parts to stick. Failure to properly clean
your sprayer will damage the unit. Taking the time to clean your sprayer immediately after
use will help your sprayer last longer and work correctly. If you are finished with the project
or are not going to use the sprayer within the day, you must follow these instructions for
proper clean up. Never store the sprayer longer than 30 minutes without cleaning.
1. Unplug your sprayer from the electrical outlet.
2. Empty any remaining (stain or paint) material from the container.
3. Fill container approximately 1/2 full with appropriate cleaning solution.
For latex, use warm soapy water; for oil-based, use a cleaning solution
recommended by the material manufacturer. (See Figure B.)
4. Plug sprayer into an electrical outlet.
5. Press the switch of the sprayer until the cleaning solution passes through the spray
nozzle for several seconds.
6. Remove container and properly discard the cleaning solution.
7. Unplug the sprayer from the electrical outlet.
STEP TWO: CLEAN UP INSTRUCTIONS FOR THE SPRAY TIP
Use the brush (included) to complete the following steps.
1. Unplug the sprayer from the electrical outlet.
2. Unscrew the container and discard any remaining cleaning solution.
3. Remove the pick-up tube from the cylinder housing and clean it with warm, soapy
water.* (See Figure C.)
4. Unscrew the spray tip housing, remove the winged spray cap and the inner spacer.
Clean all three with warm, soapy water.* (See Figure D.)
5. Clean the sealing ring found between the container and the housing with warm,
soapy water*.
6. Clean the cylinder housing and the unit with warm, soapy water*, including the brass
needle and housing. Thoroughly clean the inlet port.
7. Let the components dry thoroughly and reassemble the unit.
8. Store the unit.
* If you've been using oil-based liquids, clean these parts with whatever the liquid manufacturer recommends
(probably mineral spirits).
MAINTENANCE
Air filters should be inspected periodically. If it is excessively dirty, follow these steps to
remove and replace: (Figure E.)
1. Keeping the sprayer upright at all times, remove two screws from the motor lid and
remove the lid.
2. Replace filters (P/N C817343) and reinstall lid.
SERVICING A DOUBLE-INSULATED PRODUCT
In a double-insulated product, two systems of insulation are provided instead of grounding.
No grounding means is provided on a double insulated product, nor should a means of
grounding be added to the product. Servicing of a double-insulated product requires extreme
care and knowledge of the system and should only be done by qualified service personnel.
Replacement parts for a double-insulated product must be identical to those parts in
the product.
CLEAN UP & MAINTENANCE
COMMAND MAX™ HVLP SPRAYER
(C800766)
9
A
1 B
C
D
E
ENGLISH