Alarm Management - CASATELLI LEONARDO 8ET Generalidades - Advertencias - Instalación - Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

13

ALARM MANAGEMENT

If an anomaly occurs in the operation, the following procedure is activated:
1) acoustic alarm (beep);
2) one of the following system LEDs lights up:
3) if the anomaly concerns an error, the stove will switch off.
Press and hold the
CODE
ERROR/WARNING
E001
Defective control panel
E002
Remote control communication signal error
E004
Communication error
Ignition failure error
E101
E106
Pellet probe alarm
E108
Pressure or thermal safety error
E110
Temperature probe malfunction
E111
Fume probe malfunction
Scheduled maintenance warning.
A002
(flashing icon)
A004
Low battery
A005
Hall sensor malfunction
----
Stove cleaning
----
Ignition failure error
After checking the message type, it is possible to reset the alarm by pressing the on/off key
E108
If the error code is "
(Fig. 13) (to be performed by the technical support centre).
Before switching on again, check that:
the stove has cooled down
the burn pot is clean and free from ash residue or pellets
the burn pot is correctly positioned in its seat
the fire box and tank doors are firmly closed.
* If the event of a black-out, the stove must be reconfigured when the electricity comes back on (see par. "Initial
settings" of this manual).
"cancel" key to display the error code:
DESCRIPTION
", manually re-arm the thermostat on the back of the stove before resetting the alarm
004778330 - 16/07/2020
;
POSSIBLE CAUSES
Defective control panel
Defective control panel
Connection cable between board and control panel
interrupted or disconnected.
If it appears during the configuration change, ignore
this error
Insufficient pellets
Pellet quality
Faulty ignition system
Dirty burn pot
Pellet probe disconnected or faulty
Dirty fume evacuation system
Worn sealing gaskets
Insufficient combustion air
Problems of overheating of the pellet tank
Defective air probe
Defective fume temperature probe
Periodically, the stove requires maintenance by a
specialist technician
The back-up battery (mod. CR2032) on the electronic
board is low *
Hall sensor on fumes fan disconnected or faulty
Combustion chamber, burn pot or dirty fume evacuation.
Detached or blocked pressure detection tubes.
Blocked combustion air intake.
No pellets: Ignition resistor faulty;
Worn gaskets; Incorrect burn pot position
LED
for a few seconds.
Fig. 13
49

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Leonardo 9et

Tabla de contenido